Can Epidural Dexamethasone Reduce Patient-Controlled Epidural Consumption of Fentanyl and Levobupivacaine in Laboring Women? A Double-Blind, Randomized, Placebo-Controlled Trial.

Can Epidural Dexamethasone Reduce Patient-Controlled Epidural Consumption of Fentanyl and Levobupivacaine in Laboring Women? A Double-Blind, Randomized, Placebo-Controlled Trial.

Dhal, Ankur;Mitra, Sukanya;Saroa, Richa;Singh, Jasveer;Mehra, Reeti;
Journal of obstetrics and gynaecology of India 2019 Vol. 69 pp. 258-265
261
dhal2019canjournal

Abstract

The efficacy of a single bolus dose of epidural dexamethasone added to levobupivacaine-fentanyl combination for labor analgesia has not been studied. In this randomized double-blind controlled trial, we assessed the effect of epidural dexamethasone in reducing the hourly average consumption of epidural levobupivacaine-fentanyl combination in laboring parturients and to study its effect on pain score, maternal satisfaction, maternal and neonatal outcome.Sixty adult ASA I-II single-gestation full-term primigravid laboring parturients with cervical dilation ≤ 5 cm were randomly assigned to two equal-sized groups. Combined spinal-epidural block was performed in all the parturients. After placing the epidural catheter in epidural space, 8 mg of preservative-free dexamethasone was administered to the dexamethasone group, and 0.9% saline to the placebo group. All parturients received continuous background infusion of 5 ml of 0.1% levobupivacaine with 2 μg/ml of fentanyl with the provision of patient-controlled bolus of 5 ml of 0.1% levobupivacaine with 2 μg/ml of fentanyl (lockout interval 15 min). The primary outcome measure was the hourly total consumption of levobupivacaine-fentanyl mixture. The secondary outcome measures were maternal satisfaction, pain score, maternal hemodynamic parameters, fetal heart rate, duration of second stage of labor, mode of delivery, Apgar scores and adverse effects.Hourly drug consumption and hourly bolus requirement were significantly lower in the dexamethasone group than placebo group (6.97 ml ± 1.22 vs. 8.40 ml ± 2.59 and 0.41 ± 0.26 vs. 0.72 ± 0.55, respectively,  = 0.008 for both). There were no significant differences in other outcome measures.Epidural dexamethasone significantly decreased average hourly drug consumption and the number of boluses in laboring parturients, thus providing epidural drug dose-sparing effect.

Citation

ID: 68383
Ref Key: dhal2019canjournal
Use this key to autocite in SciMatic or Thesis Manager

References

Blockchain Verification

Account:
NFT Contract Address:
0x95644003c57E6F55A65596E3D9Eac6813e3566dA
Article ID:
68383
Unique Identifier:
10.1007/s13224-018-1189-2
Network:
Scimatic Chain (ID: 481)
Loading...
Blockchain Readiness Checklist
Authors
Abstract
Journal Name
Year
Title
5/5
Creates 1,000,000 NFT tokens for this article
Token Features:
  • ERC-1155 Standard NFT
  • 1 Million Supply per Article
  • Transferable via MetaMask
  • Permanent Blockchain Record
Blockchain QR Code
Scan with Saymatik Web3.0 Wallet

Saymatik Web3.0 Wallet