Initial Clinical Experience with a Modulated Holmium Laser Pulse—Moses Technology: Does It Enhance Laser Lithotripsy Efficacy?

Initial Clinical Experience with a Modulated Holmium Laser Pulse—Moses Technology: Does It Enhance Laser Lithotripsy Efficacy?

Mullerad, Michael;Aguinaga, Jonatan R. A.;Aro, Tareq;Kastin, Alexander;Goldin, Oleg;Kravtsov, Alexander;Assadi, Akram;Badaan, Shadie;Amiel, Gilad E.;
rambam maimonides medical journal 2017 Vol. 8 pp. e0038-
650
mullerad2017initialrambam

Abstract

Objective The Lumenis® High-power Holmium Laser (120H) has a unique modulated pulse mode, Moses™ technology. Moses technology modulates the laser pulse to separate the water (vapor bubble), then deliver the remaining energy through the bubble. Proprietary laser fibers were designed for the Moses technology. Our aim was to compare stone lithotripsy with and without the Moses technology. Methods We designed a questionnaire for the urologist to fill immediately after each ureteroscopy in which the Lumenis 120H was used. We compared procedures with (n=23) and without (n=11) the use of Moses technology. Surgeons ranked the Moses technology in 23 procedures, in comparison to regular lithotripsy (worse, equivalent, better, much better). Laser working time and energy use were collected from the Lumenis 120H log. Results During 4 months, five urologists used the Lumenis 120H in 34 ureteroscopy procedures (19 kidney stones, 15 ureteral stones; 22 procedures with a flexible ureteroscope, and 12 with a semi-rigid ureteroscope). Three urologists ranked Moses technology as much better or better in 17 procedures. In 2 cases, it was ranked equivalent, and in 4 cases ranking was not done. Overall, laser lithotripsy with Moses technology utilized laser energy in less time to achieve a satisfying stone fragmentation rate of 95.8 mm3/min versus 58.1 mm3/min, P=0.19. However, this did not reach statistical significance. Conclusion The new Moses laser technology demonstrated good stone fragmentation capabilities when used in everyday clinical practice.

Citation

ID: 29238
Ref Key: mullerad2017initialrambam
Use this key to autocite in SciMatic or Thesis Manager

References

Blockchain Verification

Account:
NFT Contract Address:
0x95644003c57E6F55A65596E3D9Eac6813e3566dA
Article ID:
29238
Unique Identifier:
1dfe62b74aa69449b040b3bc28d9709a
Network:
Scimatic Chain (ID: 481)
Loading...
Blockchain Readiness Checklist
Authors
Abstract
Journal Name
Year
Title
5/5
Creates 1,000,000 NFT tokens for this article
Token Features:
  • ERC-1155 Standard NFT
  • 1 Million Supply per Article
  • Transferable via MetaMask
  • Permanent Blockchain Record
Blockchain QR Code
Scan with Saymatik Web3.0 Wallet

Saymatik Web3.0 Wallet