Clinical and economic aspects of newborn screening for severe combined immunodeficiency: DEPISTREC study results.

Thomas, Caroline;Durand-Zaleski, Isabelle;Frenkiel, Jérôme;Mirallié, Sophie;Léger, Alexandra;Cheillan, David;Picard, Capucine;Mahlaoui, Nizar;Riche, Valéry-Pierre;Roussey, Michel;Sébille, Véronique;Rabetrano, Hasina;Dert, Cécile;Fischer, Alain;Audrain, Marie;
clinical immunology (orlando, fla) 2019 Vol. 202 pp. 33-39
314
thomas2019clinicalclinical

Abstract

Severe combined immunodeficiency (SCID) refers to a group of genetic disorders characterized by greatly compromised cellular and humoral immunity. Children with SCID are asymptomatic at birth, but they die from infections within the first months of life if not treated. Quantification of T-cell receptor excision circles is an extremely sensitive screening method for detecting newborns who may have SCID.The goal of the DEPISTREC study was to evaluate the feasibility of nationwide newborn screening for severe T-cell lymphopenia in France as well as its economic and clinical utility.The test universally used for neonatal screening for SCID was the quantification of TRECs on Guthrie cards. We compared a group of 190,517 babies from 48 maternities across the country who underwent newborn SCID screening with a control group of 1.4 million babies out of whom 28 were diagnosed with SCID without such screening during the course of the study.Within the screening group, 62 babies were found to be lymphopenic, including three with SCID. The cost of screening ranged from 4.7€ to €8.15 per newborn. The average 18-month cost was €257,574 vs €204,697 in the control group.In this large-scale study, we demonstrate that routine SCID screening is feasible and effective. This screening offers the additional benefit of aiding in the diagnosis of non-SCID lymphopenia. Economic evaluation allowed us to calculate the cost per test. Newborn screening may also prevent death by SCID before any curative treatment can be administered. The difference in cost between screened and control children could not be ascertained because of the very low numbers and death of one of the children tested.

Citation

ID: 12437
Ref Key: thomas2019clinicalclinical
Use this key to autocite in SciMatic or Thesis Manager

References

Blockchain Verification

Account:
NFT Contract Address:
0x95644003c57E6F55A65596E3D9Eac6813e3566dA
Article ID:
12437
Unique Identifier:
S1521-6616(19)30005-1
Network:
Scimatic Chain (ID: 481)
Loading...
Blockchain Readiness Checklist
Authors
Abstract
Journal Name
Year
Title
5/5
Creates 1,000,000 NFT tokens for this article
Token Features:
  • ERC-1155 Standard NFT
  • 1 Million Supply per Article
  • Transferable via MetaMask
  • Permanent Blockchain Record
Blockchain QR Code
Scan with Saymatik Web3.0 Wallet

Saymatik Web3.0 Wallet