Changes in Electrocardiographic P Wave Parameters after Cryoballoon Ablation and Their Association with Atrial Fibrillation Recurrence.

Changes in Electrocardiographic P Wave Parameters after Cryoballoon Ablation and Their Association with Atrial Fibrillation Recurrence.

Kizilirmak, Filiz;Demir, Gultekin Gunhan;Gokdeniz, Tayyar;Gunes, Haci Murat;Cakal, Beytullah;Guler, Ekrem;Karaca, İbrahim Oguz;Omaygenç, Mehmet Onur;Yılmaz, Fatih;Olgun, Fatih Erkam;Kilicaslan, Fethi;
annals of noninvasive electrocardiology : the official journal of the international society for holter and noninvasive electrocardiology, inc 2016 Vol. 21 pp. 580-587
266
kizilirmak2016changesannals

Abstract

Changes in P wave parameters after circumferential pulmonary vein isolation (CPVI) have been previously identified. In this study, we aimed to determine the changes in P wave parameters surface electrocardiogram (ECG) after cryoballoon ablation (CBA) for atrial fibrillation (AF) and evaluate their relationship with AF recurrence.Sixty-one patients (mean age 53 ± 11 years, 50.8% male) with paroxysmal AF who underwent CBA were enrolled. A surface ECG was obtained from all patients immediately before the procedure, and repeated 12 hours after the procedure. P wave amplitude (Pamp), P wave duration (Pwd), and P wave dispersion (Pdis) values in preprocedural and postprocedural ECGs were measured and compared. Recurrence rates of AF in 3, 6, and 9 months following ablation were recorded for all patients. Changes in P wave parameters were compared between patients with and without AF recurrence.Compared to preprocedural measurements, Pamp (from 0.58 ± 0.18 mV at baseline to 0.48 ± 0.17 mV, P < 0.001), Pwd (from 109.72 ± 18.43 ms at baseline to 91.36 ± 22.53 ms, P < 0.001), and Pdis (from 55.44 ± 20.45 ms at baseline to 45.30 ± 15.31 ms, P < 0.001) were significantly decreased after CBA. The difference in Pamp between pre- and postprocedural values (∆Pamp) was significantly higher in patients without AF recurrence compared to those with recurrence (0.10 ± 0.06 mV vs 0.04 ± 0.01 mV, P = 0.002). There was no difference in Pwd difference (∆Pwd) and Pdis difference (∆Pdis) between patients with and without AF recurrence (P > 0.05).Pamp, Pwd, and Pdis parameters exhibited significant decrease after CBA compared to preprocedural measurements. Decreased Pamp was shown to be a predictor for good clinical outcomes following CBA.

Citation

ID: 59207
Ref Key: kizilirmak2016changesannals
Use this key to autocite in SciMatic or Thesis Manager

References

Blockchain Verification

Account:
NFT Contract Address:
0x95644003c57E6F55A65596E3D9Eac6813e3566dA
Article ID:
59207
Unique Identifier:
10.1111/anec.12364
Network:
Scimatic Chain (ID: 481)
Loading...
Blockchain Readiness Checklist
Authors
Abstract
Journal Name
Year
Title
5/5
Creates 1,000,000 NFT tokens for this article
Token Features:
  • ERC-1155 Standard NFT
  • 1 Million Supply per Article
  • Transferable via MetaMask
  • Permanent Blockchain Record
Blockchain QR Code
Scan with Saymatik Web3.0 Wallet

Saymatik Web3.0 Wallet