Concepts for designing and fabricating metal implant frameworks for hybrid implant prostheses.

Concepts for designing and fabricating metal implant frameworks for hybrid implant prostheses.

Drago, Carl;Howell, Kent;
journal of prosthodontics : official journal of the american college of prosthodontists 2012 Vol. 21 pp. 413-24
138
drago2012conceptsjournal

Abstract

Edentulous patients have reported difficulties in managing complete dentures; they have also reported functional concerns and higher expectations regarding complete dentures than the dentists who have treated them. Some of the objectives of definitive fixed implant prosthodontic care include predictable, long-term prostheses, improved function, and maintenance of alveolar bone. One of the keys to long-term clinical success is the design and fabrication of metal frameworks that support implant prostheses. Multiple, diverse methods have been reported regarding framework design in implant prosthodontics. Original designs were developed empirically, without the benefit of laboratory testing. Prosthetic complications reported after occlusal loading included screw loosening, screw fracture, prosthesis fracture, crestal bone loss around implants, and implant loss. Numerous authors promoted accurately fitting frameworks; however, it has been noted that metal frameworks do not fit accurately. Passively fitting metal implant frameworks and implants have not been realized. Biologic consequences of ill-fitting frameworks were not well understood. Basic engineering principles were then incorporated into implant framework designs; however, laboratory testing was lacking. It has been reported that I- and L-beam designs were the best clinical option. With the advent of CAD/CAM protocols, milled titanium frameworks became quite popular in implant prosthodontics. The purpose of this article is to discuss current and past literature regarding implant-retained frameworks for full-arch, hybrid restorations. Benefits, limitations, and complications associated with this type of prosthesis will be reviewed. This discussion will include the relative inaccuracy of casting/implant fit and improved accuracy noted with CAD/CAM framework/implant fit; cantilever extensions relative to the A/P implant spread; and mechanical properties associated with implant frameworks including I- and L-beam designs. Guidelines will be proposed for use by clinicians and laboratory technicians in designing implant-retained frameworks.

Citation

ID: 42074
Ref Key: drago2012conceptsjournal
Use this key to autocite in SciMatic or Thesis Manager

References

Blockchain Verification

Account:
NFT Contract Address:
0x95644003c57E6F55A65596E3D9Eac6813e3566dA
Article ID:
42074
Unique Identifier:
10.1111/j.1532-849X.2012.00835.x
Network:
Scimatic Chain (ID: 481)
Loading...
Blockchain Readiness Checklist
Authors
Abstract
Journal Name
Year
Title
5/5
Creates 1,000,000 NFT tokens for this article
Token Features:
  • ERC-1155 Standard NFT
  • 1 Million Supply per Article
  • Transferable via MetaMask
  • Permanent Blockchain Record
Blockchain QR Code
Scan with Saymatik Web3.0 Wallet

Saymatik Web3.0 Wallet