Radionuclide spatial distribution and dose deposition for in vitro assessments of Pb-αVCAM-1 targeted alpha therapy.

Radionuclide spatial distribution and dose deposition for in vitro assessments of Pb-αVCAM-1 targeted alpha therapy.

Frelin-Labalme, Anne-Marie;Roger, Thomas;Falzone, Nadia;Quan Lee, Boon;Sibson, Nicola R;Vallis, Katherine A;Bernaudin, Myriam;Valable, Samuel;Corroyer-Dulmont, Aurélien;
Medical physics 2019
191
frelinlabalme2019radionuclidemedical

Abstract

Targeted alpha therapy (TAT) takes advantage of the short-range and high-linear energy transfer of α-particles and is increasingly used, especially for the treatment of metastatic lesions. Nevertheless, dosimetry of α-emitters is challenging for the very same reasons, even for in vitro experiments. Assumptions, such as the uniformity of the distribution of radionuclides in the culture medium, are commonly made, which could have a profound impact on dose calculations. In this study we measured the spatial distribution of α-emitting Pb coupled to an anti-VCAM-1 antibody ( Pb-αVCAM-1) and its evolution over time in the context of in vitro irradiations.Two experimental setups were implemented without cells to measure α-particle count rates and energy spectra in culture medium containing 15 kBq of Pb-α-VCAM-1. Silicon detectors were placed above and below cell culture dishes for 20 h. One of the dishes had a 2.5-µm-thick mylar-base allowing easy detection of the α-particles. Monte Carlo simulations were performed to analyze experimental spectra. Experimental setups were modeled and α-energy spectra were simulated in the silicon detectors for different decay positions in the culture medium. Simulated spectra were then used to deconvolute experimental spectra to determine the spatial distribution of Pb-αVCAM-1 in the medium. This distribution was finally used to calculate the dose deposition in cell culture experiments.Experimental count rates and energy spectra showed differences in measurements taken at the top and the bottom of dishes and temporal variations that did not follow Pb decay. The radionuclide spatial distribution was shown to be composed of a uniform distribution and concentration gradients at the top and the bottom, which were subjected to temporal variations that may be explained by gravity and electrostatic attraction. The absorbed dose in cells calculated from this distribution was compared with the dose expected for a uniform and static distribution and found to be 1.75 times higher, which is highly significant to interpret biological observations.This study demonstrated that accurate dosimetry of α-emitters requires the experimental determination of radionuclide spatial and temporal distribution and highlighted that in vitro assessment of dose for TAT cannot only rely on a uniform distribution of activity in the culture medium. The reliability and reproducibility of future experiments should benefit from specifically developed dosimetry tools and methods.

Access

Citation

ID: 99375
Ref Key: frelinlabalme2019radionuclidemedical
Use this key to autocite in SciMatic or Thesis Manager

References

Blockchain Verification

Account:
NFT Contract Address:
0x95644003c57E6F55A65596E3D9Eac6813e3566dA
Article ID:
99375
Unique Identifier:
10.1002/mp.13969
Network:
Scimatic Chain (ID: 481)
Loading...
Blockchain Readiness Checklist
Authors
Abstract
Journal Name
Year
Title
5/5
Creates 1,000,000 NFT tokens for this article
Token Features:
  • ERC-1155 Standard NFT
  • 1 Million Supply per Article
  • Transferable via MetaMask
  • Permanent Blockchain Record
Blockchain QR Code
Scan with Saymatik Web3.0 Wallet

Saymatik Web3.0 Wallet