Initial operation results of NE213 scintillation detector for time-resolved measurements on triton burnup in KSTAR.

Initial operation results of NE213 scintillation detector for time-resolved measurements on triton burnup in KSTAR.

Jo, Jungmin;Cheon, MunSeong;Kim, Junghee;Lim, Soobin;Isobe, M;Ogawa, K;Nishitani, T;Park, Seugil;Murata, I;Chung, Kyoung-Jae;Hwang, Y S;
The Review of scientific instruments 2018 Vol. 89 pp. 10I118
182
jo2018initialthe

Abstract

In time-resolved measurement for triton burnup in Korea Superconducting Tokamak Advanced Research (KSTAR) deuterium plasmas, an NE213 liquid scintillation detector was installed and operated during the 2017 KSTAR campaign. The detector is composed of an NE213 scintillator (50 mm in diameter and 10 mm in thickness) and a photomultiplier tube (PMT). The PMT anode signal was processed under a data acquisition system which contains a field programmable gate array circuit and pulse processing software that is capable of discriminating gamma-ray and neutron pulse signals. In order to determine an appropriate threshold level for the 14 MeV neutron signal resulting from triton burnup, the NE213 scintillation detector was calibrated by using d-d and d-t neutron generators at the National Fusion Research Institute and Intense 14 MeV Neutron Source Facility, OKTAVIAN, Osaka University, Japan. The detector was installed on KSTAR with a 10 mm thick soft-iron stray magnetic field shield and a radiation shield which consists of 100 mm thick lead blocks and 200 mm thick borated polyethylene blocks. A discrimination range for d-t neutron was determined based on test results from neutron generators and KSTAR. Data points selected from the discrimination range were consistent with the classical triton confinement characteristics. In conclusion, under condition of an input counting rate of 1.9 × 10 counts per second (CPS), the detector is able to measure triton burnup signals up to 500 CPS for various plasma parameters.

Citation

ID: 97188
Ref Key: jo2018initialthe
Use this key to autocite in SciMatic or Thesis Manager

References

Blockchain Verification

Account:
NFT Contract Address:
0x95644003c57E6F55A65596E3D9Eac6813e3566dA
Article ID:
97188
Unique Identifier:
10.1063/1.5039308
Network:
Scimatic Chain (ID: 481)
Loading...
Blockchain Readiness Checklist
Authors
Abstract
Journal Name
Year
Title
5/5
Creates 1,000,000 NFT tokens for this article
Token Features:
  • ERC-1155 Standard NFT
  • 1 Million Supply per Article
  • Transferable via MetaMask
  • Permanent Blockchain Record
Blockchain QR Code
Scan with Saymatik Web3.0 Wallet

Saymatik Web3.0 Wallet