Large Structural Shear Deformation and Failure Monitoring Using Bend Losses in Polymer Optical Fibre.

Large Structural Shear Deformation and Failure Monitoring Using Bend Losses in Polymer Optical Fibre.

Yuen, Terry Y P;Tsai, Cheng-An;Deb, Trissa;Lin, Yu-Hsiang;Nyienyi, June;Wan, Kai Tai;Huang, Qunxian;
Sensors (Basel, Switzerland) 2019 Vol. 20
195
yuen2019largesensors

Abstract

Rapid identification of structural damage positions is essential to the post-disaster rehabilitation of structures and infrastructures. Large shear deformation, e.g., shear failure of bridge piers, shear-slip of slopes, and shear cracking of structural walls, is often the cause of structural instability. Distributed optical fibre sensing (DOFS) techniques have an advantage over point-based sensors in terms of spatial continuous structural condition monitoring. This paper presents the development of new measurement theory and algorithm to evaluate the structural shear deflection based on the large beam deflection and optical bend loss theories. The proposed technique adopted a photon-counting Optical Time Domain Reflectometer (ν-OTDR) with polymer optical fibres (POFs) which has a large deformation measurement range and high spatial resolution. In the experiment, shear deformation events can be successfully detected and evaluated from the proposed technique. When the normalised shear deformation is larger than 0.2, both the event locations and the magnitudes can be accurately determined. When normalised shear deformation is lesser than 0.2, the error in the magnitude evaluation increased, but the event location can be found with an absolute error <0.5 m. Multiple shear events can be treated as independent events when they are separated by more than 5 m. Various configurations of POFs attached to concrete beam specimens for rupture failure monitoring were also studied. The configuration that could maximise the POF curvature at the beam failure produced the largest ν-OTDR signals. In other configurations in which the POFs were only stretched at failure, the signals were less strong and were influenced by the POF-structure bonding strength.

Access

Citation

ID: 88899
Ref Key: yuen2019largesensors
Use this key to autocite in SciMatic or Thesis Manager

References

Blockchain Verification

Account:
NFT Contract Address:
0x95644003c57E6F55A65596E3D9Eac6813e3566dA
Article ID:
88899
Unique Identifier:
E195
Network:
Scimatic Chain (ID: 481)
Loading...
Blockchain Readiness Checklist
Authors
Abstract
Journal Name
Year
Title
5/5
Creates 1,000,000 NFT tokens for this article
Token Features:
  • ERC-1155 Standard NFT
  • 1 Million Supply per Article
  • Transferable via MetaMask
  • Permanent Blockchain Record
Blockchain QR Code
Scan with Saymatik Web3.0 Wallet

Saymatik Web3.0 Wallet