Water T Mapping in Fatty Infiltrated Thigh Muscles of Patients With Neuromuscular Diseases Using a T -Prepared 3D Turbo Spin Echo With SPAIR.

Water T Mapping in Fatty Infiltrated Thigh Muscles of Patients With Neuromuscular Diseases Using a T -Prepared 3D Turbo Spin Echo With SPAIR.

Schlaeger, Sarah;Weidlich, Dominik;Klupp, Elisabeth;Montagnese, Federica;Deschauer, Marcus;Schoser, Benedikt;Bublitz, Sarah;Ruschke, Stefan;Zimmer, Claus;Rummeny, Ernst J;Kirschke, Jan S;Karampinos, Dimitrios C;
Journal of magnetic resonance imaging : JMRI 2019
314
schlaeger2019waterjournal

Abstract

Muscle water T (T ) has been proposed as a biomarker to monitor disease activity and therapy effectiveness in patients with neuromuscular diseases (NMD). Multi-echo spin-echo (MESE) is known to be affected by fatty infiltration. A T -prepared 3D turbo spin echo (TSE) is an alternative method for T mapping, but has been only applied in healthy muscles.To examine the performance of T -prepared 3D TSE in combination with spectral adiabatic inversion recovery (SPAIR) in measuring T in fatty infiltrated muscles based on simulations and in vivo measurements in thigh muscles of patients with NMD.Prospective.One healthy volunteer, 34 NMD patients.T -prepared stimulated echo acquisition mode (STEAM) magnetic resonance spectroscopy (MRS), SPAIR STEAM MRS, and SPAIR T -prepared STEAM MRS were performed in the subcutaneous fat of a healthy volunteer's thigh. T mapping based on SPAIR 2D MESE and SPAIR T -prepared 3D TSE was performed in the NMD patients' thigh region. Multi-TE STEAM MRS was performed for measuring a reference T at different thigh locations.The behavior of the fat spectrum in the SPAIR T -prepared 3D TSE was simulated using Bloch simulations. The in vivo T results of the imaging methods were compared to the in vivo T MRS results.Pearson correlation coefficient with slope and intercept, relative error.The simulated T for the SPAIR T -prepared 3D TSE sequence remained constant within a relative error of not more than 4% up to a fat fraction of 80%. In vivo T values of SPAIR T -prepared 3D TSE were in good agreement with the T values of STEAM MRS (R = 0.86; slope = 1.12; intercept = -1.41 ms). In vivo T values of SPAIR 2D MESE showed large deviations from the T values of STEAM MRS (R = 0.14; slope = 0.32; intercept = 38.83 ms).The proposed SPAIR T -prepared 3D TSE shows reduced sensitivity to fatty infiltration for T mapping in the thigh muscles of NMD patients.1 TECHNICAL EFFICACY: Stage 1.

Citation

ID: 78279
Ref Key: schlaeger2019waterjournal
Use this key to autocite in SciMatic or Thesis Manager

References

Blockchain Verification

Account:
NFT Contract Address:
0x95644003c57E6F55A65596E3D9Eac6813e3566dA
Article ID:
78279
Unique Identifier:
10.1002/jmri.27032
Network:
Scimatic Chain (ID: 481)
Loading...
Blockchain Readiness Checklist
Authors
Abstract
Journal Name
Year
Title
5/5
Creates 1,000,000 NFT tokens for this article
Token Features:
  • ERC-1155 Standard NFT
  • 1 Million Supply per Article
  • Transferable via MetaMask
  • Permanent Blockchain Record
Blockchain QR Code
Scan with Saymatik Web3.0 Wallet

Saymatik Web3.0 Wallet