Design Strategies for Biocontainment Units to Reduce Risk During Doffing of High-level Personal Protective Equipment.

Design Strategies for Biocontainment Units to Reduce Risk During Doffing of High-level Personal Protective Equipment.

Wong, Maria F;Matić, Zorana;Campiglia, Gabrielle C;Zimring, Craig M;Mumma, Joel M;Kraft, Colleen S;Casanova, Lisa M;Durso, Francis T;Walsh, Victoria L;Shah, Puja Y;Shane, Andi L;Jacob, Jesse T;Dubose, Jennifer R;
Clinical infectious diseases : an official publication of the Infectious Diseases Society of America 2019 Vol. 69 pp. S241-S247
347
wong2019designclinical

Abstract

Few data exist to guide the physical design of biocontainment units, particularly the doffing area. This can impact the contamination risk of healthcare workers (HCWs) during doffing of personal protective equipment (PPE).In phase I of our study, we analyzed simulations of a standard patient care task with 56 trained HCWs focusing on doffing of high-level PPE. In phase II, using a rapid cycle improvement approach, we tested different balance aids and redesigned doffing area layouts with 38 students. In phase III, we tested 1 redesigned layout with an additional 10 trained HCWs. We assessed the effectiveness of design changes on improving the HCW performance (measured by occurrence and number of risky behaviors) and reducing the physical and cognitive load by comparing the results from phase I and phase III.The physical load was highest when participants were removing their shoe covers without any balance aid; the use of a chair required the lowest physical effort, followed by horizontal and vertical grab bars. In the revised design (phase III), the overall performance of participants improved. There was a significant decrease in the number of HCW risky behaviors (P = .004); 5 risky behaviors were eliminated and 2 others increased. There was a significant decrease in physical load when removing disposable shoe covers (P = .04), and participants reported a similar workload in the redesigned doffing layout (P = .43).Through optimizing the design and layout of the doffing space, we reduced risky behaviors of HCWs during doffing of high-level PPE.

Citation

ID: 61838
Ref Key: wong2019designclinical
Use this key to autocite in SciMatic or Thesis Manager

References

Blockchain Verification

Account:
NFT Contract Address:
0x95644003c57E6F55A65596E3D9Eac6813e3566dA
Article ID:
61838
Unique Identifier:
10.1093/cid/ciz617
Network:
Scimatic Chain (ID: 481)
Loading...
Blockchain Readiness Checklist
Authors
Abstract
Journal Name
Year
Title
5/5
Creates 1,000,000 NFT tokens for this article
Token Features:
  • ERC-1155 Standard NFT
  • 1 Million Supply per Article
  • Transferable via MetaMask
  • Permanent Blockchain Record
Blockchain QR Code
Scan with Saymatik Web3.0 Wallet

Saymatik Web3.0 Wallet