Comparing dose rates near a radioactive patient evaluated using various source models: point, line, cylinder, and anthropomorphic phantoms.

Comparing dose rates near a radioactive patient evaluated using various source models: point, line, cylinder, and anthropomorphic phantoms.

Liu, Yi-Ching;Lee, Kuo-Wei;Sheu, Rong-Jiun;
health physics 2015 Vol. 109 pp. 69-77
245
liu2015comparinghealth

Abstract

This study investigated radiation exposures from nuclear medicine patients by systematically comparing the dose rates calculated using various source models, ranging from simplified point, line, and cylinder sources to high-quality anthropomorphic phantoms. Three widely used radionuclides, (99m)Tc, (18)F, and I(131), were considered in these source models with uniform or organ-dependent distributions. Conducting Monte Carlo simulations with anthropomorphic phantoms is a realistic but time-consuming approach. The point source model is simple but too conservative, overestimating dose rates by approximately a factor of 2 at a distance of 30 cm and by 30-40% at 1 m. Both the line and cylinder source models provided improved estimates, reducing the overestimation of dose rates to 10-20% at distances of interest. The line source model was comparable to the cylinder source model because of the offset of two competing effects (i.e., attenuation and buildup) caused by the source volume. The influence of various photon energies and cylinder sizes on the result of compensating errors was examined to evaluate the effective range of the line source model. The line source model, which is relatively easy to implement and predicts slightly conservative dose rates, is considered the most practical method for calculating dose rates near radioactive patients. An application of the line source model to 51 post-thyroidectomy patients in Taiwan was demonstrated. The consistency between calculations and measurements was satisfactory after considering the room-scattering effect.

Citation

ID: 51324
Ref Key: liu2015comparinghealth
Use this key to autocite in SciMatic or Thesis Manager

References

Blockchain Verification

Account:
NFT Contract Address:
0x95644003c57E6F55A65596E3D9Eac6813e3566dA
Article ID:
51324
Unique Identifier:
10.1097/HP.0000000000000294
Network:
Scimatic Chain (ID: 481)
Loading...
Blockchain Readiness Checklist
Authors
Abstract
Journal Name
Year
Title
5/5
Creates 1,000,000 NFT tokens for this article
Token Features:
  • ERC-1155 Standard NFT
  • 1 Million Supply per Article
  • Transferable via MetaMask
  • Permanent Blockchain Record
Blockchain QR Code
Scan with Saymatik Web3.0 Wallet

Saymatik Web3.0 Wallet