Use of pulsed electron avalanche knife (PEAK) PlasmaBlade™ in patients undergoing implantation of subcutaneous implantable cardioverter-defibrillator.

Use of pulsed electron avalanche knife (PEAK) PlasmaBlade™ in patients undergoing implantation of subcutaneous implantable cardioverter-defibrillator.

Kaya, Elif;Siebermair, Johannes;Azizy, Obayda;Dobrev, Dobromir;Rassaf, Tienush;Wakili, Reza;
international journal of cardiology heart & vasculature 2019 Vol. 24 pp. 100390
313
kaya2019useinternational

Abstract

Surgical implantation of subcutaneous implantable cardioverter-defibrillators (S-ICD) requires preparation of a deeper and larger pocket. Infection and bleeding complications are reported, particularly in patients requiring antiplatelet therapy (APT) or being on oral anticoagulation (OAC), with rates up to 25%. The pulsed electron avalanche knife (PEAK) PlasmaBlade™ has been reported to reduce bleeding complications. The purpose of this study was to evaluate the safety and feasibility of a PEAK guided S-ICD implantation with respect to perioperative complications.We enrolled 36 consecutive patients (75% male; mean age 52.1 ± 14.4 years) undergoing S-ICD implantation. Periprocedural safety endpoints comprised major complications including pocket hematomas, wound infections, bleeding (BARC ≥2) or events requiring interventions. Patients were divided into three groups according to management of their anticoagulation: i.) APT, n = 15 (41.7%); ii.) OAC, n = 10 patients (27.8%); iii.) none (neither OAC nor APT), n = 11 (30.6%). Mean procedure duration was 33.1 ± 13.4 min. Mean length of hospital stay was 3.3 ± 2.1 days. Overall analysis showed no differences between the 3 groups with respect to major complications, major bleeding episodes or other procedural parameters, beside a trend towards more minor hematomas in the OAC group (OAC: 22.2% vs. APT: 11.4% vs. none: 9.1%;  = 0.15).The results of our pilot study suggest that intermuscular S-ICD implantation using PEAK is safe and potentially beneficial in patients receiving OAC or APT with respect to prevention of bleeding complications. These results support the rationale for large prospective controlled trials evaluating a beneficial effect of PEAK use in S-ICD implantation procedures.

Citation

ID: 5066
Ref Key: kaya2019useinternational
Use this key to autocite in SciMatic or Thesis Manager

References

Blockchain Verification

Account:
NFT Contract Address:
0x95644003c57E6F55A65596E3D9Eac6813e3566dA
Article ID:
5066
Unique Identifier:
10.1016/j.ijcha.2019.100390
Network:
Scimatic Chain (ID: 481)
Loading...
Blockchain Readiness Checklist
Authors
Abstract
Journal Name
Year
Title
5/5
Creates 1,000,000 NFT tokens for this article
Token Features:
  • ERC-1155 Standard NFT
  • 1 Million Supply per Article
  • Transferable via MetaMask
  • Permanent Blockchain Record
Blockchain QR Code
Scan with Saymatik Web3.0 Wallet

Saymatik Web3.0 Wallet