Use of pulmonary artery catheter in coronary artery bypass graft. Costs and long-term outcomes.

Use of pulmonary artery catheter in coronary artery bypass graft. Costs and long-term outcomes.

Xu, Fei;Wang, Qian;Zhang, Heng;Chen, Sipeng;Ao, Hushan;
PloS one 2015 Vol. 10 pp. e0117610-
594
xu2015useplos

Abstract

BACKGROUND:Pulmonary artery catheters (PAC) are used widely to monitor hemodynamics in patients undergoing coronary bypass graft (CABG) surgery. However, recent studies have raised concerns regarding both the effectiveness and safety of PAC. Therefore, our aim was to determine the effects of the use of PAC on the short- and long-term health and economic outcomes of patients undergoing CABG. METHODS:1361 Chinese patients who consecutively underwent isolated, primary CABG at the Cardiovascular Institute of Fuwai Hospital from June 1, 2012 to December 31, 2012 were included in this study. Of all the patients, 453 received PAC during operation (PAC group) and 908 received no PAC therapy (control group). Short-term and long-term mortality and major complications were analyzed with multivariate regression analysis and propensity score matched-pair analysis was used to yield two well-matched groups for further comparison. RESULTS:The patients who were managed with PAC more often received intraoperative vasoactive drugs dopamine (70.9% vs. 45.5%; P<0.001) and epinephrine (7.7% vs. 2.6%; P<0.001). In addition, costs for initial hospitalization were higher for PAC patients ($14,535 vs. $13,873, respectively, p = 0.004). PAC use was neither associated with the perioperative mortality or major complications, nor was it associated with long-term mortality and major adverse cardiac and cerebrovascular events. In addition, comparison between two well-matched groups showed no significant differences either in baseline characteristics or in short-term and long-term outcomes. CONCLUSIONS:There is no clear indication of any benefit or harm in managing CABG patients with PAC. However, use of PAC in CABG is more expensive. That is, PAC use increased costs without benefit and thus appears unjustified for routine use in CABG surgery.

Citation

ID: 4598
Ref Key: xu2015useplos
Use this key to autocite in SciMatic or Thesis Manager

References

Blockchain Verification

Account:
NFT Contract Address:
0x95644003c57E6F55A65596E3D9Eac6813e3566dA
Article ID:
4598
Unique Identifier:
Network:
Scimatic Chain (ID: 481)
Loading...
Blockchain Readiness Checklist
Authors
Abstract
Journal Name
Year
Title
5/5
Creates 1,000,000 NFT tokens for this article
Token Features:
  • ERC-1155 Standard NFT
  • 1 Million Supply per Article
  • Transferable via MetaMask
  • Permanent Blockchain Record
Blockchain QR Code
Scan with Saymatik Web3.0 Wallet

Saymatik Web3.0 Wallet