Ta ion implanted nanoridge-platform for enhanced vascular responses.

Ta ion implanted nanoridge-platform for enhanced vascular responses.

Jang, Tae-Sik;Lee, Jae Hwan;Kim, Sungwon;Park, Cheonil;Song, Juha;Jae, Hwan Jun;Kim, Hyoun-Ee;Chung, Jin Wook;Jung, Hyun-Do;
biomaterials 2019 Vol. 223 pp. 119461
192
jang2019tabiomaterials

Abstract

Bare metal stents are commonly used in interventional cardiology; they provide successful treatment because of their excellent mechanical properties, expandability ratios, and flexibility. However, their insufficient vascular affinity can induce the development of neointimal hyperplasia following arterial injury and subsequent smooth muscle cell overgrowth in the lumen of a stented vessel. Nanoengineering of the bare metal stent surface is a valuable strategy for eliciting favorable vascular responses. In this study, we introduce a target-ion-induced plasma sputtering (TIPS) technique to fabricate a platform with a favorable endothelial environment. This technique enables the simple single-step production of a Ta-implanted nanoridged surface on a stent with a complex 3D geometry that shows a clear tendency to become oriented parallel to the direction of blood flow. Moreover, the nanoridges developed show good structural integrity and mechanical stability, resulting in apparently stable morphologies under high strain rates. In vitro cellular responses to the Co-Cr, such as endothelialization, platelet activation, and blood coagulation, are considerably altered after TIPS treatment; endothelium formation is rapid and surface thrombogenicity is low. An in vivo rabbit iliac artery model is used to confirm that the nanoridged surface facilitates rapid re-endothelialization and limits the formation of neointima compared to the bare stent. These results indicate that the Ta ion implanted nanoridge platform fabricated using the TIPS technique has immense potential as a solution for in-stent restenosis and ensuring the long-term patency of bare metal stents.

Citation

ID: 43773
Ref Key: jang2019tabiomaterials
Use this key to autocite in SciMatic or Thesis Manager

References

Blockchain Verification

Account:
NFT Contract Address:
0x95644003c57E6F55A65596E3D9Eac6813e3566dA
Article ID:
43773
Unique Identifier:
S0142-9612(19)30560-5
Network:
Scimatic Chain (ID: 481)
Loading...
Blockchain Readiness Checklist
Authors
Abstract
Journal Name
Year
Title
5/5
Creates 1,000,000 NFT tokens for this article
Token Features:
  • ERC-1155 Standard NFT
  • 1 Million Supply per Article
  • Transferable via MetaMask
  • Permanent Blockchain Record
Blockchain QR Code
Scan with Saymatik Web3.0 Wallet

Saymatik Web3.0 Wallet