Upside-down position leads to choroidal expansion and anterior chamber shallowing: OCT study.

Upside-down position leads to choroidal expansion and anterior chamber shallowing: OCT study.

Li, Fei;Li, Hao;Yang, Jianlong;Liu, Jiang;Tin, Aung;Zhang, Xiulan;
the british journal of ophthalmology 2019
263
li2019upsidedownthe

Abstract

To determine whether dynamic changes in choroidal thickness (CT) cause shallowing of the anterior chamber.34 healthy volunteers were enrolled. The participants in our study adopted the upside-down position for 1.5 min, which was the model we used to study the dynamic changes in CT. Intraocular pressure (IOP) elevation, optical coherence tomography images of the choroid and anterior chamber were obtained at baseline, after being in an upside-down position in an inversion machine and after 15 min of rest. The changes in IOP, anterior chamber and choroidal blood flow between the baseline and the upside-down position were compared.Sixty-eight eyes from 34 subjects were analysed. After being in upside-down position for 1.5 min, there was a significant increase in CT from 226.39±52.44 µm to 238.34±54.84 µm (p<0.001). Choroidal flow index decreased from 0.3357±0.0251 to 0.3004±0.0190 in upside-down position, and there was a decrease in anterior chamber depth (3.21±0.22 mm to 3.13±0.21 mm, p<0.001) and angle opening distance at 500 µm from the scleral spur (0.65±0.24 mm to 0.58±0.20 mm, p=0.007). Pearson correlation analysis showed that the increase in CT was positively related with CT at baseline CT (p=0.001).When the body position changed from sitting to upside-down position, there was choroidal thickening, anterior chamber shallowing and IOP elevation with reduced choroidal blood flow. The data provide evidence about the relationship between choroid expansion and shallowing of the anterior chamber, which may be of relevance for the pathogenesis of angle closure.

Citation

ID: 43771
Ref Key: li2019upsidedownthe
Use this key to autocite in SciMatic or Thesis Manager

References

Blockchain Verification

Account:
NFT Contract Address:
0x95644003c57E6F55A65596E3D9Eac6813e3566dA
Article ID:
43771
Unique Identifier:
bjophthalmol-2019-314418
Network:
Scimatic Chain (ID: 481)
Loading...
Blockchain Readiness Checklist
Authors
Abstract
Journal Name
Year
Title
5/5
Creates 1,000,000 NFT tokens for this article
Token Features:
  • ERC-1155 Standard NFT
  • 1 Million Supply per Article
  • Transferable via MetaMask
  • Permanent Blockchain Record
Blockchain QR Code
Scan with Saymatik Web3.0 Wallet

Saymatik Web3.0 Wallet