Topical vasodilator response in skeletonized internal mammary artery: Is there really a difference?

Topical vasodilator response in skeletonized internal mammary artery: Is there really a difference?

Shah, Syed Raza;Shah, Syed Arbab;Jangda, Muhammad Ahmed;Yaqub, Mohammad Danial;Jangda, Ayesha Altaf;Khan, Maham;Khan, Muhammad Asim;Tomkins, Brian;
avicenna journal of medicine 2017 Vol. 7 pp. 23-27
169
shah2017topicalavicenna

Abstract

Aim of the Study: Coronary artery bypass graft surgery is the gold standard for the treatment of multivessel and left main coronary artery disease. However, there is considerable debate that whether left internal mammary artery (IMA) should be taken as pedicled or skeletonized. This study was conducted to assess the difference in blood flow after the application of topical vasodilator in skeletonized and pedicled IMA. Materials and Methods: In this study, each patient underwent either skeletonized (n = 25) or pedicled IMA harvesting (n = 25). The type of graft on each individual patient was decided randomly. Intraoperative variables such as conduit length and blood flow were measured by the surgeon himself. The length of the grafted IMA was carefully determined in vivo, with the proximal and distal ends attached, from the first rib to IMA divergence. The IMA flow was measured on two separate occasions, before and after application of topical vasodilator. Known cases of subclavian artery stenosis and previous sternal radiation were excluded from the study. Results: The blood flow before the application of topical vasodilator was similar in both the groups (P = 0.227). However, the flow was significantly less in pedicled than skeletonized IMA after application of vasodilator (P < 0.0001). Similarly, the length of skeletonized graft was significantly higher than the length of pedicled graft (P < 0.0001). Conclusion: Our study signifies that skeletonization of IMA results in increased graft length and blood flow after the application of topical vasodilator. However, we recommend that long-term clinical trials should be conducted to fully determine long-term patency rates of skeletonized IMA.

Citation

ID: 39366
Ref Key: shah2017topicalavicenna
Use this key to autocite in SciMatic or Thesis Manager

References

Blockchain Verification

Account:
NFT Contract Address:
0x95644003c57E6F55A65596E3D9Eac6813e3566dA
Article ID:
39366
Unique Identifier:
48919ef58a8f640c65f75d98adeaa4bb
Network:
Scimatic Chain (ID: 481)
Loading...
Blockchain Readiness Checklist
Authors
Abstract
Journal Name
Year
Title
5/5
Creates 1,000,000 NFT tokens for this article
Token Features:
  • ERC-1155 Standard NFT
  • 1 Million Supply per Article
  • Transferable via MetaMask
  • Permanent Blockchain Record
Blockchain QR Code
Scan with Saymatik Web3.0 Wallet

Saymatik Web3.0 Wallet