Automated interpretable detection of myocardial infarction fusing energy entropy and morphological features.

Automated interpretable detection of myocardial infarction fusing energy entropy and morphological features.

Han, Chuang;Shi, Li;
computer methods and programs in biomedicine 2019 Vol. 175 pp. 9-23
225
han2019automatedcomputer

Abstract

The 12 leads electrocardiogram (ECG) is an effective tool to diagnose myocardial infarction (MI) on account of its inexpensive, noninvasive and convenient. Many methodologies have been widely adopted to detect it. However, much existing method did not integrate with diagnostic logic of clinician and practical application. The aim of the paper is to provide an automated interpretable detection method of myocardial infarction.The paper presents a novel method fusing energy entropy and morphological features for MI detection via 12 leads ECG. Specifically, ECG signals are firstly decomposed by maximal overlap discrete wavelet packet transform (MODWPT), then energy entropy is calculated from the decomposed coefficients as global features. Area, kurtosis coefficient, skewness coefficient and standard deviation extracted from QRS wave and ST-T segment of ECG beat are computed as local morphological features. Combining global features based on record and local features based on beat for single lead, all the 12 leads features are fused as the ultimate feature vector. What's more, different methods including principal component analysis (PCA), linear discriminant analysis (LDA) and locality preserving projection (LPP) are employed to reduce the computational complexity and redundant information. Meanwhile, principal component features are ranked by F-value. To evaluate the proposed method, PTB (Physikalisch-Technische Bundesanstalt) database and inter-patient paradigm are employed.Compared with different algorithms, support vector machine (SVM) using radial basis kernel function combined with 10-fold cross validation achieves the best average performance with accuracy of 99.81%, sensitivity of 99.56%, precision of 99.74% and F1 of 99.70% based on 18 features in the intra-patient paradigm. By contrast, the accuracy is 92.69% with only 22 features for the inter-patient paradigm.The experimental results present a superior performance compared to the state-of-the-art method. Meanwhile, above approach has the characteristic of interpretability according with diagnostic logic and strategy of clinician and specific change of ECG for MI.

Citation

ID: 36234
Ref Key: han2019automatedcomputer
Use this key to autocite in SciMatic or Thesis Manager

References

Blockchain Verification

Account:
NFT Contract Address:
0x95644003c57E6F55A65596E3D9Eac6813e3566dA
Article ID:
36234
Unique Identifier:
S0169-2607(19)30153-1
Network:
Scimatic Chain (ID: 481)
Loading...
Blockchain Readiness Checklist
Authors
Abstract
Journal Name
Year
Title
5/5
Creates 1,000,000 NFT tokens for this article
Token Features:
  • ERC-1155 Standard NFT
  • 1 Million Supply per Article
  • Transferable via MetaMask
  • Permanent Blockchain Record
Blockchain QR Code
Scan with Saymatik Web3.0 Wallet

Saymatik Web3.0 Wallet