Hot isostatic pressure treatment of 3D printed Ti6Al4V alters surface modifications and cellular response.

Hot isostatic pressure treatment of 3D printed Ti6Al4V alters surface modifications and cellular response.

Berger, Michael B;Jacobs, Thomas W;Boyan, Barbara D;Schwartz, Zvi;
journal of biomedical materials research part b, applied biomaterials 2019
268
berger2019hotjournal

Abstract

Additive manufacturing can be used to create personalized orthopedic and dental implants with varying geometries and porosities meant to mimic morphological properties of bone. These qualities can alleviate stress shielding and increase osseointegration through bone ingrowth, but at the expense of reduced fatigue properties compared to machined implants, and potential for loose build particle erosion. Hot isostatic pressure (HIP) treatment is used to increase fatigue resistance; implant surface treatments like grit-blasting and acid-etching create microroughness and reduce the presence of loose particles. However, it is not known how HIP treatment affects surface treatments and osseointegration of the implant to bone. We manufactured two titanium-aluminum-vanadium constructs, one with simple through-and-through porosity and one possessing complex trabecular bone-like porosity. We observed HIP treatment varied in effect and was dependent on architecture. Micro/meso/nano surface properties generated by grit-blasting and acid-etching were altered on biomimetic HIP-treated constructs. Human mesenchymal stem cells (MSCs) were cultured on constructs fabricated +/- HIP and subsequently surface-treated. MSCs were sensitive to 3D-architecture, exhibiting greater osteogenic differentiation on constructs with complex trabecular bone-like porosity. HIP-treatment did not alter the osteogenic response of MSCs to these constructs. Thus, HIP may provide mechanical and biological advantages during implant osseointegration and function.

Citation

ID: 28455
Ref Key: berger2019hotjournal
Use this key to autocite in SciMatic or Thesis Manager

References

Blockchain Verification

Account:
NFT Contract Address:
0x95644003c57E6F55A65596E3D9Eac6813e3566dA
Article ID:
28455
Unique Identifier:
10.1002/jbm.b.34474
Network:
Scimatic Chain (ID: 481)
Loading...
Blockchain Readiness Checklist
Authors
Abstract
Journal Name
Year
Title
5/5
Creates 1,000,000 NFT tokens for this article
Token Features:
  • ERC-1155 Standard NFT
  • 1 Million Supply per Article
  • Transferable via MetaMask
  • Permanent Blockchain Record
Blockchain QR Code
Scan with Saymatik Web3.0 Wallet

Saymatik Web3.0 Wallet