Imaging practice in low-grade gliomas among European specialized centers and proposal for a minimum core of imaging.

Imaging practice in low-grade gliomas among European specialized centers and proposal for a minimum core of imaging.

Freyschlag, Christian F; Krieg, Sandro M; Kerschbaumer, Johannes; Pinggera, Daniel; Forster, Marie-Therese; Cordier, Dominik; Rossi, Marco; Miceli, Gabriele; Roux, Alexandre; Reyes, Andrés; Sarubbo, Silvio; Smits, Anja; Sierpowska, Joanna; Robe, Pierre A; Rutten, Geert-Jan; Santarius, Thomas; Matys, Tomasz; Zanello, Marc; Almairac, Fabien; Mondot, Lydiane; Jakola, Asgeir S; Zetterling, Maria; Rofes, Adrià; von Campe, Gord; Guillevin, Remy; Bagatto, Daniele; Lubrano, Vincent; Rapp, Marion; Goodden, John; De Witt Hamer, Philip C; Pallud, Johan; Bello, Lorenzo; Thomé, Claudius; Duffau, Hugues; Mandonnet, Emmanuel
journal of neuro-oncology 2018 Vol. 139 pp. 699-711
9
freyschlag2018imaging

Abstract

Imaging studies in diffuse low-grade gliomas (DLGG) vary across centers. In order to establish a minimal core of imaging necessary for further investigations and clinical trials in the field of DLGG, we aimed to establish the status quo within specialized European centers. An online survey composed of 46 items was sent out to members of the European Low-Grade Glioma Network, the European Association of Neurosurgical Societies, the German Society of Neurosurgery and the Austrian Society of Neurosurgery. A total of 128 fully completed surveys were received and analyzed. Most centers (n = 96, 75%) were academic and half of the centers (n = 64, 50%) adhered to a dedicated treatment program for DLGG. There were national differences regarding the sequences enclosed in MRI imaging and use of PET, however most included T1 (without and with contrast, 100%), T2 (100%) and TIRM or FLAIR (20, 98%). DWI is performed by 80% of centers and 61% of centers regularly performed PWI. A minimal core of imaging composed of T1 (w/wo contrast), T2, TIRM/FLAIR, PWI and DWI could be identified. All morphologic images should be obtained in a slice thickness of ≤ 3 mm. No common standard could be obtained regarding advanced MRI protocols and PET. We believe that our study makes a significant contribution to the literature because we were able to determine similarities in numerous aspects of LGG imaging. Using the proposed "minimal core of imaging" in clinical routine will facilitate future cooperative studies.

Citation

ID: 283568
Ref Key: freyschlag2018imaging
Use this key to autocite in SciMatic or Thesis Manager

References

Blockchain Verification

Account:
NFT Contract Address:
0x95644003c57E6F55A65596E3D9Eac6813e3566dA
Article ID:
283568
Unique Identifier:
10.1007/s11060-018-2916-3
Network:
Scimatic Chain (ID: 481)
Loading...
Blockchain Readiness Checklist
Authors
Abstract
Journal Name
Year
Title
5/5
Creates 1,000,000 NFT tokens for this article
Token Features:
  • ERC-1155 Standard NFT
  • 1 Million Supply per Article
  • Transferable via MetaMask
  • Permanent Blockchain Record
Blockchain QR Code
Scan with Saymatik Web3.0 Wallet

Saymatik Web3.0 Wallet