Node positive breast cancer: Concordance between baseline PET/CT and sentinel node assessment after neoadjuvant therapy.

Node positive breast cancer: Concordance between baseline PET/CT and sentinel node assessment after neoadjuvant therapy.

Christin, Oscar Leopoldo;Kuten, Jonathan;Even-Sapir, Einat;Klausner, Joseph;Menes, Tehillah S;
Surgical oncology 2019 Vol. 30 pp. 1-5
47
christin2019nodesurgical

Abstract

Sentinel node biopsy for axillary staging in node positive patients after neoadjuvant treatment is controversial, mainly due to high false negative rates. We examined the concordance between the location of the hot nodes identified on PET-CT at presentation with the location of the sentinel nodes.Fifty-eight breast cancer patients undergoing neoadjuvant treatment between January 2013 and September 2018 who had positive regional lymph nodes on PET/CT, and a SPECT/CT lymphoscintigraphy completed before sentinel node biopsy were included. Patient, tumor and treatment characteristics were collected. Images of PET/CT were compared to images of SPECT/CT lymphoscintigraphy post treatment and concordance between location of the hot nodes on PET/CT with the sentinel nodes visualized on SPECT/CT was assessed. Association between patient, tumor and treatment characteristics and concordance between the sentinel node and the hot nodes was determined.Sentinel nodes were identified in 53 (91%) of the cases in surgery. In 25 (43%) patients, axillary nodes were positive after treatment. In 16 (28%; 95% CI 18, 40) the sentinel node was not one of the hot nodes seen on PET/CT at presentation. Twenty-three (40%) patients had excision of additional axillary nodes. In two patients with non-concordant sentinel nodes, the sentinel node was falsely negative.In node positive patients who undergo neoadjuvant treatment, the sentinel node visualized on lymphatic mapping is not necessarily one of the hot nodes identified on PET/CT at presentation. These findings underline the importance of marking the pathologically proven lymph node and excising it as well as the sentinel nodes after treatment.

Citation

ID: 279284
Ref Key: christin2019nodesurgical
Use this key to autocite in SciMatic or Thesis Manager

References

Blockchain Verification

Account:
NFT Contract Address:
0x95644003c57E6F55A65596E3D9Eac6813e3566dA
Article ID:
279284
Unique Identifier:
10.1016/j.suronc.2019.05.006
Network:
Scimatic Chain (ID: 481)
Loading...
Blockchain Readiness Checklist
Authors
Abstract
Journal Name
Year
Title
5/5
Creates 1,000,000 NFT tokens for this article
Token Features:
  • ERC-1155 Standard NFT
  • 1 Million Supply per Article
  • Transferable via MetaMask
  • Permanent Blockchain Record
Blockchain QR Code
Scan with Saymatik Web3.0 Wallet

Saymatik Web3.0 Wallet