Diagnostic accuracy of unenhanced CT texture analysis to differentiate mass-forming pancreatitis from pancreatic ductal adenocarcinoma

Diagnostic accuracy of unenhanced CT texture analysis to differentiate mass-forming pancreatitis from pancreatic ductal adenocarcinoma

Shuai Ren;Rui Zhao;Jingjing Zhang;Kai Guo;Xiaoyu Gu;Shaofeng Duan;Zhongqiu Wang;Rong Chen;Shuai Ren;Rui Zhao;Jingjing Zhang;Kai Guo;Xiaoyu Gu;Shaofeng Duan;Zhongqiu Wang;Rong Chen;
abdominal radiology 2020 Vol. 45 pp. 1524-1533
156
ren2020abdominaldiagnostic

Abstract

To investigate the value of texture analysis on unenhanced computed tomography (CT) to potentially differentiate mass-forming pancreatitis (MFP) from pancreatic ductal adenocarcinoma (PDAC). A retrospective study consisting of 109 patients (30 MFP patients vs 79 PDAC patients) who underwent preoperative unenhanced CT between January 2012 and December 2017 was performed. Synthetic minority oversampling technique (SMOTE) algorithm was adopted to reconstruct and balance MFP and PDAC samples. A total of 396 radiomic features were extracted from unenhanced CT images. Mann–Whitney U test and minimum redundancy maximum relevance (MRMR) methods were used for the purpose of dimension reduction. Predictive models were constructed using random forest (RF) method, and were validated using leave group out cross-validation (LGOCV) method. Diagnostic performance of the predictive model, including sensitivity, specificity, accuracy, positive predicting value (PPV), and negative predicting value (NPV), was recorded. We applied 200% of SMOTE to MFP and PDAC patients, resulting in 90 MFP patients compared with 120 PDAC patients. Dimension reduction steps yielded 30 radiomic features using Mann–Whitney U test and MRMR methods. Ten radiomic features were retained using RF method. Four most predictive parameters, including GreyLevelNonuniformity_angle90_offset1, VoxelValueSum, HaraVariance, and ClusterProminence_AllDirection_offset1_SD, were used to generate the predictive model with preferable 92.2% sensitivity, 94.2% specificity, 93.3% accuracy, 92.2% PPV, and 94.2% NPV. Finally, in LGOCV analysis, a high pooled mean sensitivity, specificity, and accuracy (82.6%, 80.8%, and 82.1%, respectively) indicate a relatively reliable and stable predictive model. Unenhanced CT texture analysis can be a promising noninvasive method in discriminating MFP from PDAC.

Citation

ID: 262178
Ref Key: ren2020abdominaldiagnostic
Use this key to autocite in SciMatic or Thesis Manager

References

Blockchain Verification

Account:
NFT Contract Address:
0x95644003c57E6F55A65596E3D9Eac6813e3566dA
Article ID:
262178
Unique Identifier:
doi:10.1007/s00261-020-02506-6
Network:
Scimatic Chain (ID: 481)
Loading...
Blockchain Readiness Checklist
Authors
Abstract
Journal Name
Year
Title
5/5
Creates 1,000,000 NFT tokens for this article
Token Features:
  • ERC-1155 Standard NFT
  • 1 Million Supply per Article
  • Transferable via MetaMask
  • Permanent Blockchain Record
Blockchain QR Code
Scan with Saymatik Web3.0 Wallet

Saymatik Web3.0 Wallet