reprodutibilidade da classificação ultra-sonográfica de niamey na avaliação da fibrose periportal na esquistossomose mansônica reproducibility of ultrasonography in the assessment of periportal fibrosis according to niamey criteria in patients with schistosomiasis mansoni

reprodutibilidade da classificação ultra-sonográfica de niamey na avaliação da fibrose periportal na esquistossomose mansônica reproducibility of ultrasonography in the assessment of periportal fibrosis according to niamey criteria in patients with schistosomiasis mansoni

;Germana Titonelli Santos;Danilo Moulin Sales;Alberto Ribeiro de Souza Leão;José Eduardo Mourão Santos;Luciane Aparecida Kopke de Aguiar;Paulo Eugênio Brant;David Carlos Shigueoka;Ramiro Colleoni Neto;Giuseppe D'Ippolito
india international conference on information processing, iicip 2016 - proceedings 2007 Vol. 40 pp. 377-381
296
santos2007radiologiareprodutibilidade

Abstract

OBJETIVO: Medir a concordância intra- e interobservador da classificação ultra-sonográfica qualitativa para graduar a fibrose periportal adotada no encontro de Niamey em 1996. MATERIAIS E MÉTODOS: No período de fevereiro de 2005 a março de 2006 foi realizado estudo prospectivo, observacional e transversal em 30 pacientes esquistossomóticos, sem outras hepatopatias associadas, submetidos a ultra-sonografia abdominal e classificados segundo os critérios de Niamey. Os exames foram realizados por dois radiologistas de forma independente em diferentes momentos: durante o exame dinâmico (primeiro momento) e 30 e 90 dias depois (segundo e terceiro momentos) do exame, por meio da documentação fotográfica analisada em estação de trabalho. A concordância intra- e interobservador foi avaliada pelo teste kappa. RESULTADOS: A concordância intra-observador medida pelo teste kappa foi 0,43 para o observador 1 e 0,57 para o observador 2. A concordância interobservador durante o estudo dinâmico e na avaliação fotográfica foi, respectivamente, de 0,46 e 0,71. CONCLUSÃO: O uso do ultra-som para classificar a fibrose periportal segundo o protocolo de Niamey apresentou uma reprodutibilidade que variou de moderada a substancial.
OBJECTIVE: To determine the intra- and interobserver agreement in the classification of periportal fibrosis, according to the criteria defined at the Niamey Workshop of 1996. MATERIALS AND METHODS: A prospective, observational and transverse study was developed in the period between February, 2005 and March, 2006, in 30 schistosomal patients with no other hepatic findings associated, submitted to abdominal ultrasound. Ultrasonographic studies were independently performed and reviewed by two radiologists at three different moments: the dynamic examination itself (first moment), 30 and 90 days later (second and third moments), by means of the images review performed in a workstation. Intra- and interobserver agreement was evaluated by means of the kappa test. RESULTS: Intraobserver agreement was 0.43 for the first, and 0.57 for the second observer. Interobserver agreement as regards the dynamic examination and images review was respectively 0.46 and 0.71. CONCLUSION: Ultrasonography demonstrated moderate to substantial reproducibility in the classification of periportal fibrosis according to the Niamey criteria.

Citation

ID: 243290
Ref Key: santos2007radiologiareprodutibilidade
Use this key to autocite in SciMatic or Thesis Manager

References

Blockchain Verification

Account:
NFT Contract Address:
0x95644003c57E6F55A65596E3D9Eac6813e3566dA
Article ID:
243290
Unique Identifier:
10.1590/S0100-39842007000600005
Network:
Scimatic Chain (ID: 481)
Loading...
Blockchain Readiness Checklist
Authors
Abstract
Journal Name
Year
Title
5/5
Creates 1,000,000 NFT tokens for this article
Token Features:
  • ERC-1155 Standard NFT
  • 1 Million Supply per Article
  • Transferable via MetaMask
  • Permanent Blockchain Record
Blockchain QR Code
Scan with Saymatik Web3.0 Wallet

Saymatik Web3.0 Wallet