An objective scatter index cutoff point as a powerful objective criterion for preoperative nuclear cataract decision-making based on ROC analysis.

An objective scatter index cutoff point as a powerful objective criterion for preoperative nuclear cataract decision-making based on ROC analysis.

Monferrer-Adsuara, Clara;Mata-Moret, Lucía;Castro-Navarro, Verónica;Hernández-Garfella, Marisa;Gracia-García, Alicia;Ortiz-Salvador, Miguel;Remolí-Sargues, Lidia;Cervera-Taulet, Enrique;
journal of cataract and refractive surgery 2019
221
monferreradsuara2019anjournal

Abstract

To assess the correlation between clinical cataract surgery indication and the objective scatter index (OSI) by defining the optimal OSI cutoff point in the surgery scheduling.Ophthalmology service, Consorcio Hospital General Universitario, Valencia, Spain.Prospective triple-masked randomized single-center study.Patients with cataractous eyes were recruited, and those with anterior segment disease, abnormal posterior pole, and/or previous ocular surgery were excluded. The principle of double-pass aberrometry was used by the main investigator to determine an OSI, after measuring subjective refraction and corrected distance visual acuity (CDVA), and then slitlamp evaluation was carried out by an independent researcher. The surgical decision was based on the current protocol according to the European guidelines. Correlation between the surgical decision, CDVA, and OSI were analyzed and an OSI discriminative value was calculated, implementing a receiver operating characteristic (ROC) curve.The study comprised 106 eyes (73 patients). The analysis established an inverse linear correlation between OSI and CDVA (r = -0.455, P < .0001). The comparison of the mean OSI between the surgical group (7.05 ± 4.65 [SD]) and the nonsurgical group (2.92 ± 1.88), revealed statistically significant differences (P = 5.04 × 10). The OSI score 3.2 was determined as the optimal cutoff value to discriminate surgical treatment (sensitivity 80%, specificity 84%).An optimal OSI value, according to an ROC curve calculation, was capable of providing clinicians with a powerful criterion for preoperative decision-making, thus suggesting an end to the subjectivity implicit in the cataract surgery decision-making process.

Citation

ID: 24097
Ref Key: monferreradsuara2019anjournal
Use this key to autocite in SciMatic or Thesis Manager

References

Blockchain Verification

Account:
NFT Contract Address:
0x95644003c57E6F55A65596E3D9Eac6813e3566dA
Article ID:
24097
Unique Identifier:
S0886-3350(19)30435-3
Network:
Scimatic Chain (ID: 481)
Loading...
Blockchain Readiness Checklist
Authors
Abstract
Journal Name
Year
Title
5/5
Creates 1,000,000 NFT tokens for this article
Token Features:
  • ERC-1155 Standard NFT
  • 1 Million Supply per Article
  • Transferable via MetaMask
  • Permanent Blockchain Record
Blockchain QR Code
Scan with Saymatik Web3.0 Wallet

Saymatik Web3.0 Wallet