implante de schocket modificado em glaucomas refratários: resultados a longo prazo modified schocket implant for refractory glaucoma: long-term results

implante de schocket modificado em glaucomas refratários: resultados a longo prazo modified schocket implant for refractory glaucoma: long-term results

;João Antonio Prata Jr;Antonio Eduardo Pereira;Carlos Akira Omi
introducing innodb cluster: learning the mysql high availability stack 2000 Vol. 63 pp. 439-443
137
jr2000arquivosimplante

Abstract

Objetivo:Analisar os resultados a longo prazo obtidos com o implante de Schocket modificado. Métodos: Os prontuários de 45 pacientes (45 cirurgias) submetidas ao implante de Schocket modificado com pelo menos um ano de acompanhamento foram analisados. Estudou-se as taxas de sucesso (sucesso=Po<22 mmHg), tempo de sobrevida, diagnóstico, acompanhamento pós-operatório, Po inicial e final, redução percentual pós-operatória da pressão intra-ocular (Po) e complicações. Resultados: Após um acompanhamento médio de 31,9 ± 19,9 meses 28 casos (62,2%) foram considerados sucesso. O tempo médio de sobrevida foi de 38,9 meses com probabilidade de sucesso de 0,74 por volta dos 30 meses. A Po inicial foi de 37,2 ± 11,3 e a final de 16,3 ± 9,3 mmHg, com redução de 49,6 ± 32,6 %. A análise das taxas de sucesso e sobrevida entre os diferentes grupos diagnósticos (glaucoma e afacia, neovascular, congênito e pós-ceratoplastia) não revelou diferença estatisticamente significante. Conclusão: Os resultados sugerem que o implante de Schocket modificado propicia um controle satisfatório de glaucomas refratários a longo prazo.
Purpose: To analyze long-term results of modified Schocket implant. Methods: The records of 45 patients (45 surgeries) with at least one year follow-up who received a modified Schocket implant were analyzed. Comparisons were made regarding success rates (final IOP< 22 mmHg), survival time, diag- nosis, initial and final IOP, percentual postoperative intraocular pressure (IOP) reduction and complications. Results: After a mean follow-up of 31.9 ± 19.9 months 28 cases (62.2%) were considered successful. Mean survival time was 38.9 months and success probability around 30 months 0.74. Initial IOP was 37.2 ± 11.3 mmHg and final IOP was 16.3 ± 9.3 mmHg and postoperative IOP reduction was 49.6 ± 32.6%. Survival analysis in the different diagnosis groups (neovascular, congenital, aphakic, postkeratoplasty) did not reveal statistical significance. Conclusion: The results suggest that the modified Schocket implant provides satisfactory long-term control of refrac- tory glaucomas.

Citation

ID: 234364
Ref Key: jr2000arquivosimplante
Use this key to autocite in SciMatic or Thesis Manager

References

Blockchain Verification

Account:
NFT Contract Address:
0x95644003c57E6F55A65596E3D9Eac6813e3566dA
Article ID:
234364
Unique Identifier:
10.1590/S0004-27492000000600002
Network:
Scimatic Chain (ID: 481)
Loading...
Blockchain Readiness Checklist
Authors
Abstract
Journal Name
Year
Title
5/5
Creates 1,000,000 NFT tokens for this article
Token Features:
  • ERC-1155 Standard NFT
  • 1 Million Supply per Article
  • Transferable via MetaMask
  • Permanent Blockchain Record
Blockchain QR Code
Scan with Saymatik Web3.0 Wallet

Saymatik Web3.0 Wallet