influência do agente de união na resistência ao cisalhamento da interface titânio/polímero de vidro bonding agent influence on shear bond strength of titanium/polyglass interface

influência do agente de união na resistência ao cisalhamento da interface titânio/polímero de vidro bonding agent influence on shear bond strength of titanium/polyglass interface

;Denise Kanashiro Oyafuso;Marco Antonio Bottino;Marcos Koiti Itinoche;Anna Paula Nasraui;Elza Maria Valadares da Costa
journal of animal and plant sciences 2003 Vol. 11 pp. 203-208
187
oyafuso2003journalinfluncia

Abstract

Há poucas informações em relação à efetividade da união entre compósitos e superfícies metálicas. Este estudo avaliou a influência de dois agentes de união na resistência ao cisalhamento da interface formada pelo titânio comercialmente puro (Ti cp) e um compósito (Artglass/ Heraeus Kulzer). Vinte estruturas metálicas (4mm de diâmetro e 5mm de altura) de titânio grau 1 foram fundidas, jateadas com partículas de óxido de alumínio (250ìm) e separadas em dois grupos. Para cada grupo foi utilizado um agente de união (Sistema Siloc-Pre ou Retention Flow) como procedimento anterior à aplicação do material opaco. Sobre este foram aplicados camadas do polímero referente à dentina com o auxílio de uma matriz de teflon. A manipulação e polimerização foram realizadas de acordo com as recomendações do fabricante. Os corpos-de-prova foram armazenados em água destilada por 24 horas à 37ºC e termociclados (5º e 55ºC/ 500ciclos). O teste de resistência ao cisalhamento foi realizado em uma máquina de ensaios universal (Instron) com velocidade de 5mm/min. Os dados foram tratados estatisticamente pela Análise de Variância one-way (á=0,5). Os resultados indicaram que o sistema adesivo Retention Flow foi estatisticamente melhor do que o Siloc, com médias de 20,74MPa e 11,65MPa, respectivamente. Foi possível concluir que o sistema de união influenciou na adesão entre o titânio grau I e o polímero de vidro estudado.
There is little information regarding bond strengths of polyglass to metal alloys. This study evaluated the influence of bonding system on shear bond strength of a composite resin (Artglass/Heraeus Kulzer) to cast titanium (Ti). Twenty metallic structures (4mm in diameter, 5mm thick) of titanium grade I were cast shaped and abraded with 250mm aluminum oxide and separated into two groups. For each group was applied one bonding system (Siloc or Retention Flow) before opaque and dentin polymer superposition. This procedure was managed using teflon matrices. They were manipulated and polymerized according to the manufacturer's recommendations. The samples were stored in distilled water for 24 hours at 37º and thermocycled (5º and 55ºC/500 cycles). Shear bond strength tests were performed by using an Instron Universal testing machine at a crosshead speed of 5mm/min. Results were analyzed statistically with one-way ANOVA (a=0,5) and they indicated that the Retention Flow system was statistically better than Siloc (20.74 MPa and 11.65 MPa , respectively). It was possible to conclude that the bonding agent influenced the adhesion between polymer and cast titanium.

Citation

ID: 208708
Ref Key: oyafuso2003journalinfluncia
Use this key to autocite in SciMatic or Thesis Manager

References

Blockchain Verification

Account:
NFT Contract Address:
0x95644003c57E6F55A65596E3D9Eac6813e3566dA
Article ID:
208708
Unique Identifier:
10.1590/S1678-77572003000300009
Network:
Scimatic Chain (ID: 481)
Loading...
Blockchain Readiness Checklist
Authors
Abstract
Journal Name
Year
Title
5/5
Creates 1,000,000 NFT tokens for this article
Token Features:
  • ERC-1155 Standard NFT
  • 1 Million Supply per Article
  • Transferable via MetaMask
  • Permanent Blockchain Record
Blockchain QR Code
Scan with Saymatik Web3.0 Wallet

Saymatik Web3.0 Wallet