automated electronic medical record sepsis detection in the emergency department

automated electronic medical record sepsis detection in the emergency department

;Su Q. Nguyen;Edwin Mwakalindile;James S. Booth;Vicki Hogan;Jordan Morgan;Charles T. Prickett;John P. Donnelly;Henry E. Wang
pediatrics 2014 Vol. 2 pp. e343-
156
nguyen2014peerjautomated

Abstract

Background. While often first treated in the emergency department (ED), identification of sepsis is difficult. Electronic medical record (EMR) clinical decision tools offer a novel strategy for identifying patients with sepsis. The objective of this study was to test the accuracy of an EMR-based, automated sepsis identification system.Methods. We tested an EMR-based sepsis identification tool at a major academic, urban ED with 64,000 annual visits. The EMR system collected vital sign and laboratory test information on all ED patients, triggering a “sepsis alert” for those with ≥2 SIRS (systemic inflammatory response syndrome) criteria (fever, tachycardia, tachypnea, leukocytosis) plus ≥1 major organ dysfunction (SBP ≤ 90 mm Hg, lactic acid ≥2.0 mg/dL). We confirmed the presence of sepsis through manual review of physician, nursing, and laboratory records. We also reviewed a random selection of ED cases that did not trigger a sepsis alert. We evaluated the diagnostic accuracy of the sepsis identification tool.Results. From January 1 through March 31, 2012, there were 795 automated sepsis alerts. We randomly selected 300 cases without a sepsis alert from the same period. The true prevalence of sepsis was 355/795 (44.7%) among alerts and 0/300 (0%) among non-alerts. The positive predictive value of the sepsis alert was 44.7% (95% CI [41.2–48.2%]). Pneumonia and respiratory infections (38%) and urinary tract infection (32.7%) were the most common infections among the 355 patients with true sepsis (true positives). Among false-positive sepsis alerts, the most common medical conditions were gastrointestinal (26.1%), traumatic (25.7%), and cardiovascular (20.0%) conditions. Rates of hospital admission were: true-positive sepsis alert 91.0%, false-positive alert 83.0%, no sepsis alert 5.7%.Conclusions. This ED EMR-based automated sepsis identification system was able to detect cases with sepsis. Automated EMR-based detection may provide a viable strategy for identifying sepsis in the ED.

Citation

ID: 208514
Ref Key: nguyen2014peerjautomated
Use this key to autocite in SciMatic or Thesis Manager

References

Blockchain Verification

Account:
NFT Contract Address:
0x95644003c57E6F55A65596E3D9Eac6813e3566dA
Article ID:
208514
Unique Identifier:
10.7717/peerj.343
Network:
Scimatic Chain (ID: 481)
Loading...
Blockchain Readiness Checklist
Authors
Abstract
Journal Name
Year
Title
5/5
Creates 1,000,000 NFT tokens for this article
Token Features:
  • ERC-1155 Standard NFT
  • 1 Million Supply per Article
  • Transferable via MetaMask
  • Permanent Blockchain Record
Blockchain QR Code
Scan with Saymatik Web3.0 Wallet

Saymatik Web3.0 Wallet