experimental study on the palatability impacts of potable water as a hydronic medium

experimental study on the palatability impacts of potable water as a hydronic medium

;Robert Prybysh;Mohamed Al-Hussein;Brian Fleck;Mohtada Sadrzadeh;Jeremiah Osolu
Journal of food biochemistry 2018 Vol. 10 pp. 218-
133
prybysh2018waterexperimental

Abstract

Hydronic systems installed in buildings utilize water to transport thermal energy within the building for heating and cooling purposes. These systems can be closed loop, where the water is chemically treated and circulated indefinitely, or they can be open loop, where the water is not treated and is effluxed as a result of occupant activities, such as bathing or cooking. Water in an open loop system may circulate within the system for a limited time before it is extracted from the system by occupant activities and replaced with new water from the local water supply. The implementation of open loop hydronic systems is becoming more common in multi-unit residential buildings, even though a number of questions regarding the use of such systems remain unanswered. One concern regarding the use of circulated potable water for heating purposes is the potential effects on the occupant perceptions of the palatability of the service water being delivered to their suites. In an open-loop HVAC system (Heating Ventilating, Air Conditioning System), heating water is subject to repeated thermal cycles and continuous recirculation, which creates the potential for chemical alterations of the materials present in the water or leaching of materials from the equipment and piping. Through the use of Flavor Profile Analysis (FPA) established by the American Water Works Association, and a multi-unit HVAC system constructed in a controlled environment, the palatability effects of the operational system were evaluated for a number of scenarios. The collected feedback from the study participants was then tabulated to quantify the impacts of using potable water as a recirculating heating medium on the perceptions of the occupants. The resulting observations led us to conclude that utilizing potable water as a heating medium has a negligible effect on the palatability of water in the system for average retention times under one day, and a non-objectionable, but noticeable, effect for higher average retention times.

Citation

ID: 188991
Ref Key: prybysh2018waterexperimental
Use this key to autocite in SciMatic or Thesis Manager

References

Blockchain Verification

Account:
NFT Contract Address:
0x95644003c57E6F55A65596E3D9Eac6813e3566dA
Article ID:
188991
Unique Identifier:
10.3390/w10020218
Network:
Scimatic Chain (ID: 481)
Loading...
Blockchain Readiness Checklist
Authors
Abstract
Journal Name
Year
Title
5/5
Creates 1,000,000 NFT tokens for this article
Token Features:
  • ERC-1155 Standard NFT
  • 1 Million Supply per Article
  • Transferable via MetaMask
  • Permanent Blockchain Record
Blockchain QR Code
Scan with Saymatik Web3.0 Wallet

Saymatik Web3.0 Wallet