emg spectral analysis of incremental exercise in cyclists and non-cyclists using fourier and wavelet transforms. http://dx.doi.org/10.5007/1980-0037.2012v14n6p660

emg spectral analysis of incremental exercise in cyclists and non-cyclists using fourier and wavelet transforms. http://dx.doi.org/10.5007/1980-0037.2012v14n6p660

;Marcelo Vitor da Costa;Henrique Bortolotti;Thiago Viana Camata;Jefferson Rosa Cardoso;Rubens da Silva;Taufik Abrão;Antonio Moraes;Leandro Altimari
journal of proteome research 2012 Vol. 14 pp. 660-670
213
costa2012revista<b>emg

Abstract

The aim of this study was to compare the electromyographic indices of fatigue (slope of median frequency) calculated with the fast Fourier transform (FFT) and wavelet transform (WT) in trained and untrained individuals during cycle exercise. A second objective was to compare the variance of the spectral parameters (median frequency - MF) obtained by the FFT and WT during exercise. Twelve cyclists and non-cyclists performed a maximal incremental test to determine the peak power (Wp) and electromyographic activity of the vastus lateralis (VL), rectus femoris (RF), biceps femoris (BF), semitendinous (ST) and tibialis anterior (TA). Mean values of median frequency, determined by the FFT and WT, were used for the spectral analysis of the electromyographic signals of the studied muscles. The analyzed parameters were obtained for each time period corresponding to 0, 25, 50, 75, and 100% of total duration of the maximal incremental test. No statistically significant differences were found in the values of MF and electromyographic indices of fatigue between the two techniques (FT and WT) both in the cyclists and non-cyclists group (P>0.05). Regarding the MF variance, statistically significant differences were found in all analyzed muscles, as well as in different time periods, both in the cyclists and non-cyclists groups when comparing the FFT and WT techniques (P<0.05). The WT seems to be more adequate to dynamic tasks, since it does not require the signal to be quasi-stationary, unlike the limitation imposed upon the use of the FFT.

Citation

ID: 169609
Ref Key: costa2012revista<b>emg
Use this key to autocite in SciMatic or Thesis Manager

References

Blockchain Verification

Account:
NFT Contract Address:
0x95644003c57E6F55A65596E3D9Eac6813e3566dA
Article ID:
169609
Unique Identifier:
Network:
Scimatic Chain (ID: 481)
Loading...
Blockchain Readiness Checklist
Authors
Abstract
Journal Name
Year
Title
5/5
Creates 1,000,000 NFT tokens for this article
Token Features:
  • ERC-1155 Standard NFT
  • 1 Million Supply per Article
  • Transferable via MetaMask
  • Permanent Blockchain Record
Blockchain QR Code
Scan with Saymatik Web3.0 Wallet

Saymatik Web3.0 Wallet