Abstract
Metallic rooms as part of a complex system, like a ship, are necessarily
connected electromagnetically via apertures and cables to the outside.
Therefore, their electromagnetic shielding effectiveness (SE) is limited by
ventilation openings, cable feed-throughs and door gaps. Thus, electronic
equipment inside these rooms is susceptible to outer electromagnetic threats
like IEM (Intentional Electromagnetic Interference). Dielectric or
magnetic absorber inside such a screened room can be used in order to prevent
the SE from collapsing at the resonant frequencies. In this contribution, the
effect of different available absorber materials is compared, as well as
other properties like weight and workability. Furthermore, parameter
variations of the absorber as well as the effect of loading in form of
metallic and dielectric structures on the SE are analyzed.
Citation
ID:
162868
Ref Key:
parr2015advancesanalysis