the mechanism of “killer turn” causing residual laxity after transtibial posterior cruciate ligament reconstruction

the mechanism of “killer turn” causing residual laxity after transtibial posterior cruciate ligament reconstruction

;Yue Li;Jin Zhang;Guanyang Song;Xu Li;Hua Feng
zhongguo zhongyao zazhi 2016 Vol. 3 pp. 13-18
205
li2016asia-pacificthe

Abstract

Background: The residual laxity after transtibial posterior cruciate ligament (PCL) reconstruction has been reported by several authors. The sharp angle where the graft exits the tibial tunnel, which is known as “killer turn”, is believed to be the main reason. The purpose of this study was to reveal the mechanism of “killer turn” and its effect on both graft and tunnel inlet. Methods: A total of 60 New Zealand white rabbits were included. All transtibial PCL reconstructions were performed in vitro using Achilles tendon autograft. The cyclic loading tests were conducted when reconstructed knees were subjected to 1500 cycles of tensile force of 50 N with the angle of pull at 45° to the tibial plateau. The tunnel inlet enlargement, graft elongation, stiffness, graft displacement, load to failure, and failure site were all recorded and analysed. Results: Fifty-eight New Zealand white rabbits were available for biomechanical evaluation. The subjects had significant graft elongation and tunnel enlargement. The graft displacement increased by a mean of 0.92±0.36 mm (16.70%). At the 1500th cycle, the grafts were significantly elongated by 5.59±4.98%, and the tunnel inlet diameter was also significantly enlarged by 12.08±4.31%. There was a linear correlation between total graft displacement and the two variables (R2=0.402, F=18.515, p<0.001). The coefficient for tunnel inlet enlargement was 0.419 (p=0.006), and for graft elongation was 0.583 (p=0.002). At the load-to-failure test, the failure load was 81.19±20.13 N. Of the 58 grafts, 31 (53.45%) failed at the “killer turn”, 13 (22.41%) for the para-tunnel fracture, seven (12.07%) for the graft pull-out, and the remaining seven (12.07%) for the rupture at the mounting site. Conclusion: The mechanism of “killer turn” compromising posterior stability was that the repetitive friction between graft and tunnel inlet not only attenuated the graft, but also enlarged the tunnel inlet, leading to the displacement of the graft.

Citation

ID: 157949
Ref Key: li2016asia-pacificthe
Use this key to autocite in SciMatic or Thesis Manager

References

Blockchain Verification

Account:
NFT Contract Address:
0x95644003c57E6F55A65596E3D9Eac6813e3566dA
Article ID:
157949
Unique Identifier:
10.1016/j.asmart.2015.12.001
Network:
Scimatic Chain (ID: 481)
Loading...
Blockchain Readiness Checklist
Authors
Abstract
Journal Name
Year
Title
5/5
Creates 1,000,000 NFT tokens for this article
Token Features:
  • ERC-1155 Standard NFT
  • 1 Million Supply per Article
  • Transferable via MetaMask
  • Permanent Blockchain Record
Blockchain QR Code
Scan with Saymatik Web3.0 Wallet

Saymatik Web3.0 Wallet