preoperative planning of primary total hip arthroplasty using conventional radiographs,

preoperative planning of primary total hip arthroplasty using conventional radiographs,

;Edson Hidenori Miashiro;Edson Noboru Fujikib;Eduardo Nagashigue Yamaguchi;Takeshi Chikude;Luiz Henrique Silveira Rodrigues;Gustavo Martins Fontes;Fausto Boccatto Rosa
scientific american 2014 Vol. 49 pp. 140-148
198
miashiro2014revistapreoperative

Abstract

OBJECTIVE: the objective of this study was to present an analog method for preoperative planning of primary total hip arthroplasty procedures based on measuring the components by overlaying the transparencies of the prosthesis on the preoperative radiographs and checking the accuracy, both for predicting the size of the acetabular and femoral components used and for restoring the offset and correcting the dysmetria.METHODS: between March 2005 and July 2009, 56 primary total hip arthroplasty procedures performed on 56 patients at the Mario Covas State Hospital in Santo André were analyzed. The measurements on the femoral and acetabular components obtained through planning were compared with those that were used in the surgery. The offsets measured through the preoperative planning were compared with those measured on the postoperative radiographs. Dysmetria was evaluated before and after the operation.RESULTS: accuracy of 78.6% (p< 0.001) in predicting the size of the acetabular component and 82.2% (p < 0.001) in predicting the femoral nail was observed. The offsets measured through preoperative planning were statistically similar to the offsets measured on the postoperative radiographs. After the operation, we observed absolute equalization in 48.2% of the cases. In 87.5%, the dysmetria was less than or equal to 1 cm and in 69.6%, it was less than or equal to 0.5 cm.CONCLUSIONS: the accuracy was 78.6% and 82.2%, respectively, for the acetabular and femoral components. The offsets that were planned preoperatively were statistically similar to those measured on postoperative radiographs. We found absolute equalization in 48.2% of the cases.

Citation

ID: 153796
Ref Key: miashiro2014revistapreoperative
Use this key to autocite in SciMatic or Thesis Manager

References

Blockchain Verification

Account:
NFT Contract Address:
0x95644003c57E6F55A65596E3D9Eac6813e3566dA
Article ID:
153796
Unique Identifier:
10.1016/j.rboe.2014.03.019
Network:
Scimatic Chain (ID: 481)
Loading...
Blockchain Readiness Checklist
Authors
Abstract
Journal Name
Year
Title
5/5
Creates 1,000,000 NFT tokens for this article
Token Features:
  • ERC-1155 Standard NFT
  • 1 Million Supply per Article
  • Transferable via MetaMask
  • Permanent Blockchain Record
Blockchain QR Code
Scan with Saymatik Web3.0 Wallet

Saymatik Web3.0 Wallet