surgical outcomes of a second ahmed glaucoma valve implantation in asian eyes with refractory glaucoma

surgical outcomes of a second ahmed glaucoma valve implantation in asian eyes with refractory glaucoma

;Sze Chuan Ong;Maria Cecilia Aquino;Paul Chew;Victor Koh
chemical reviews 2020 Vol. 2020 pp. -
141
ong2020journalsurgical

Abstract

Introduction. When the initial glaucoma tube shunt fails in eyes with refractory glaucoma, one option is implantation of an additional Ahmed glaucoma valve (AGV) to control intraocular pressure (IOP). We aim to evaluate the outcomes of a second AGV in Asian glaucoma. Material and Methods. This is a retrospective interventional study, consisting of 21 eyes belonging to 20 patients which underwent a second FP7 AGV. Data collected included demographic characteristics, best corrected visual acuity, IOP, and number of medications. Both intraoperative and postoperative complications or interventions were recorded. The primary outcome measurement was success rate: complete success (IOP ≥5 mmHg and ≤21 mmHg without IOP-lowering medications) and qualified success (IOP ≥5 mmHg and ≤21 mmHg with IOP-lowering medications). Failure was defined as IOP ≥5 mmHg and ≤21 mmHg, reoperations for IOP-related indications, removal of second AGV implant, or loss of light perception. Postoperative complications were included as secondary outcomes. Results. The cumulative failure rates were 9.5%, 20.0%, 32.5%, and 46.0% at six months, one year, two years, and three years of follow-up. At final follow-up, complete success and qualified success rates were 23.8% and 33.3%, respectively; mean IOP and number of medications decreased by 5.6 mmHg (23.9%) and 1.7 mmHg (54.8%), respectively, from preoperative baseline (P<0.01). More common postoperative complications included hypertensive phase (38.1%), corneal decompensation (23.8%), and tube exposure (14.3%). Conclusion. An additional AGV implant had good short and modest long-term effectiveness in reducing IOP following a failed glaucoma tube shunt in Asian eyes, with the mentioned common postoperative complications to be actively monitored and managed.

Citation

ID: 143271
Ref Key: ong2020journalsurgical
Use this key to autocite in SciMatic or Thesis Manager

References

Blockchain Verification

Account:
NFT Contract Address:
0x95644003c57E6F55A65596E3D9Eac6813e3566dA
Article ID:
143271
Unique Identifier:
10.1155/2020/8741301
Network:
Scimatic Chain (ID: 481)
Loading...
Blockchain Readiness Checklist
Authors
Abstract
Journal Name
Year
Title
5/5
Creates 1,000,000 NFT tokens for this article
Token Features:
  • ERC-1155 Standard NFT
  • 1 Million Supply per Article
  • Transferable via MetaMask
  • Permanent Blockchain Record
Blockchain QR Code
Scan with Saymatik Web3.0 Wallet

Saymatik Web3.0 Wallet