a comparative assessment of alternatives to the full-leg radiograph for determining knee joint alignment

a comparative assessment of alternatives to the full-leg radiograph for determining knee joint alignment

;Navali Amir M;Bahari Leila Azhar;Nazari Behrouz
sports medicine, arthroscopy, rehabilitation, therapy & technology 2012 Vol. 4 pp. 40-
193
m2012sportsa

Abstract

Abstract

Background

The purpose of this study was to assess the concurrent validity of alternative measures of frontal plane knee alignment, namely the radiographic anatomic axis and two clinical measures in patients complaining of knee malalignment as compared with the mechanical axis on full-length radiograph of lower limbs.

Methods

The knee-alignment angle was measured in 100 knees of 50 subjects with the chief complaint of frontal knee malalignment according to the following methods: lower-limb mechanical axis on radiograph, lower-limb anatomic axis on radiograph, distance between medial femoral condyles or medial malleoli using a calliper and lower-limb alignment using a goniometer. Data were analyzed using Pearson’s correlation coefficient and simple linear regression.

Results

The anatomic axis best correlated with the mechanical axis (r = 0.93, P<0.001), followed closely by the intercondylar/intermalleolar distance measured by calliper (r = 0.89, P<0.001). Significant correlation was also found between the mechanical-axis angle and the lower limb axis measured by goniometer (r = 0.67, P<0.001).

Conclusions

The anatomic axis on radiograph, the calliper method and to a lesser extent the goniometer measurement appear to be valid alternatives to the mechanical axis on full-leg radiograph for determining frontal plane knee alignment. These alternative measures have the potential to provide useful information regarding knee alignment and may increase the assessment of this parameter by clinicians and researchers.

Citation

ID: 140909
Ref Key: m2012sportsa
Use this key to autocite in SciMatic or Thesis Manager

References

Blockchain Verification

Account:
NFT Contract Address:
0x95644003c57E6F55A65596E3D9Eac6813e3566dA
Article ID:
140909
Unique Identifier:
10.1186/1758-2555-4-40
Network:
Scimatic Chain (ID: 481)
Loading...
Blockchain Readiness Checklist
Authors
Abstract
Journal Name
Year
Title
5/5
Creates 1,000,000 NFT tokens for this article
Token Features:
  • ERC-1155 Standard NFT
  • 1 Million Supply per Article
  • Transferable via MetaMask
  • Permanent Blockchain Record
Blockchain QR Code
Scan with Saymatik Web3.0 Wallet

Saymatik Web3.0 Wallet