impact of very high pressure stent deployment on angiographic and long-term clinical outcomes in true coronary bifurcation lesions treated by the mini-crush stent technique: a single center experience

impact of very high pressure stent deployment on angiographic and long-term clinical outcomes in true coronary bifurcation lesions treated by the mini-crush stent technique: a single center experience

;Antoine Gerbay;Jeremy Terreaux;Alexis Cerisier;Marco Vola;Karl Isaaz
renewable energy 2017 Vol. 69 pp. 32-36
180
gerbay2017indianimpact

Abstract

Background: Percutaneous coronary intervention (PCI) for bifurcation lesions (BL) using 2 stents technique is known to be associated with high rates of procedural failure especially on the side branch (SB) mainly due to stent incomplete apposition. Stent deployment at very high pressure (SDHP) may lead to better stent expansion and apposition. However, SDHP may also be at the origin of deeper wall injury resulting into major cardiac adverse events. No data are available on evaluation of SDHP in BL treated by a mini-crush stent technique. Methods: One hundred and thirteen consecutive patients underwent PCI for BL (Medina 1, 1, 1) using a mini-crush stent technique with SDHP defined as ≥20 atm. An angiographic follow-up was performed at 6 month and clinical follow-up was obtained at a median of 3 years. Results: Stent deployment mean pressures were 20 ± 1.4 atm (range 20–25) in the main vessel (MV) and 20 ± 1.5 atm (range 20–25) in SB. Simultaneous final kissing balloon was used in 92% of cases. PCI was successful in 100%. Angiographic follow-up was obtained in 83% of patients. Restenosis rate was 13% (12% restenosis in the SB) with only one case (0.8%) of SB probable thrombosis. Another case of late stent thrombosis occurred at a 3 years clinical follow-up. Conclusion: Compared with previously published studies in which stents were deployed at lower pressure, SDHP does not increase the restenosis rate in BL using mini-crush stent technique but seems to reduce the rate of stent thrombosis.

Citation

ID: 139167
Ref Key: gerbay2017indianimpact
Use this key to autocite in SciMatic or Thesis Manager

References

Blockchain Verification

Account:
NFT Contract Address:
0x95644003c57E6F55A65596E3D9Eac6813e3566dA
Article ID:
139167
Unique Identifier:
10.1016/j.ihj.2016.05.013
Network:
Scimatic Chain (ID: 481)
Loading...
Blockchain Readiness Checklist
Authors
Abstract
Journal Name
Year
Title
5/5
Creates 1,000,000 NFT tokens for this article
Token Features:
  • ERC-1155 Standard NFT
  • 1 Million Supply per Article
  • Transferable via MetaMask
  • Permanent Blockchain Record
Blockchain QR Code
Scan with Saymatik Web3.0 Wallet

Saymatik Web3.0 Wallet