comparison of nd:yag laser posterior capsulotomy techniques: cruciate versus circular

comparison of nd:yag laser posterior capsulotomy techniques: cruciate versus circular

;R Rezaei;A Almasi-Hashiani;M Khorrambakht;A Khosravi
african renaissance 2016 Vol. 18 pp. 7-12
207
rezaei2016majallah-icomparison

Abstract

BACKGROUND AND OBJECTIVE: Nd:YAG laser posterior capsulotomy is a standard method for treatment of posterior capsule opacification (PCO) in adults. However, there is not enough information available regarding the advantages and disadvantages of its conventional techniques. This study aims to compare cruciate and circular techniques of Nd: YAG laser posterior capsulotomy. METHODS: In this clinical trial, 100 eyes of patients with posterior capsule opacification after cataract surgery were randomly divided into two groups. Cruciate capsulotomy was performed for the first group and circular capsulotomy was performed for the second group. Visual acuity, intraocular pressure, lens shifting, uveitis, macular hole and retinal detachment were examined. In addition, the energy used for rupturing the capsule was recorded. IRCT: 201207037466N4. FINDINGS: The energy used in circular capsulotomy (345±68.53) was significantly more than the energy used in cruciate capsulotomy (284.4±46.78) (p=0.001). Results showed that there is no significant difference between the two groups in terms of average visibility (p=0.859) and intraocular pressure (p=0.097). Nevertheless, these two variables increase significantly through time (p=0.001). Moreover, there is no significant difference between the two groups in terms of percentage of halo. CONCLUSION: Since improvement in visual acuity and intraocular pressure was similar in the two groups but the energy used in circular capsulotomy was more than cruciate capsulotomy, cruciate technique is the preferred method.

Citation

ID: 137945
Ref Key: rezaei2016majallah-icomparison
Use this key to autocite in SciMatic or Thesis Manager

References

Blockchain Verification

Account:
NFT Contract Address:
0x95644003c57E6F55A65596E3D9Eac6813e3566dA
Article ID:
137945
Unique Identifier:
Network:
Scimatic Chain (ID: 481)
Loading...
Blockchain Readiness Checklist
Authors
Abstract
Journal Name
Year
Title
5/5
Creates 1,000,000 NFT tokens for this article
Token Features:
  • ERC-1155 Standard NFT
  • 1 Million Supply per Article
  • Transferable via MetaMask
  • Permanent Blockchain Record
Blockchain QR Code
Scan with Saymatik Web3.0 Wallet

Saymatik Web3.0 Wallet