comparison of the short-term outcomes after postisometric muscle relaxation or kinesio taping application for normalization of the upper trapezius muscle tone and the pain relief: a preliminary study

comparison of the short-term outcomes after postisometric muscle relaxation or kinesio taping application for normalization of the upper trapezius muscle tone and the pain relief: a preliminary study

;Kuba Ptaszkowski;Lucyna Slupska;Małgorzata Paprocka-Borowicz;Anna Kołcz-Trzęsicka;Kamil Zwierzchowski;Urszula Halska;Monika Przestrzelska;Dariusz Mucha;Joanna Rosińczuk
ACS applied materials & interfaces 2015 Vol. 2015 pp. -
202
ptaszkowski2015evidence-basedcomparison

Abstract

The main purpose of the study was to evaluate the resting bioelectrical activity of the upper trapezius muscle (the UT muscle) before and after one of the two interventions: postisometric muscle relaxation (PIR) and Kinesio Taping (KT). Moreover a comparison between group results was conducted. From the initial 61 volunteers, 52 were selected after exclusion criteria and were allocated randomly to 2 groups: PIR group and KT group. Outcome measures were assessed at baseline and completion of the intervention. The primary outcome measure was change in bioelectrical activity of UT muscle evaluated by surface electromyography (sEMG). Secondary outcomes included subjective assessment of pain using visual analogue scale (VAS). Significant differences were found only in KT group: the average resting bioelectrical activity decreased by 0.8 μV (p=0.0237) and the average VAS result reduced by 2.0 points (p=0.0001). Greater decrease of VAS results was recorded in KT group compared to PIR group (p=0.0010). Both PIR and KT intervention did not influence significantly the resting bioelectrical activity of UT muscle. KT application was better for pain relief in the studied sample compared with PIR intervention.

Citation

ID: 132593
Ref Key: ptaszkowski2015evidence-basedcomparison
Use this key to autocite in SciMatic or Thesis Manager

References

Blockchain Verification

Account:
NFT Contract Address:
0x95644003c57E6F55A65596E3D9Eac6813e3566dA
Article ID:
132593
Unique Identifier:
10.1155/2015/721938
Network:
Scimatic Chain (ID: 481)
Loading...
Blockchain Readiness Checklist
Authors
Abstract
Journal Name
Year
Title
5/5
Creates 1,000,000 NFT tokens for this article
Token Features:
  • ERC-1155 Standard NFT
  • 1 Million Supply per Article
  • Transferable via MetaMask
  • Permanent Blockchain Record
Blockchain QR Code
Scan with Saymatik Web3.0 Wallet

Saymatik Web3.0 Wallet