RealDRR - rendering of realistic digitally reconstructed radiographs using locally trained image-to-image translation.

RealDRR - rendering of realistic digitally reconstructed radiographs using locally trained image-to-image translation.

Dhont, Jennifer;Verellen, Dirk;Mollaert, Isabelle;Vanreusel, Verdi;Vandemeulebroucke, Jef;
Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology 2020
246
dhont2020realdrrradiotherapy

Abstract

Digitally reconstructed radiographs (DRRs) represent valuable patient-specific pre-treatment training data for tumor tracking algorithms. However, using current rendering methods, the similarity of the DRRs to real X-ray images is limited, requires time-consuming measurements and/or are computationally expensive. In this study we present RealDRR, a novel framework for highly realistic and computationally efficient DRR rendering.RealDRR consists of two components applied sequentially to render a DRR. First, a raytracer is applied for forward projection from 3D CT data to a 2D image. Second, a conditional Generative Adverserial Network (cGAN) is applied to translate the 2D forward projection to a realistic 2D DRR. The planning CT and CBCT projections from a CIRS thorax phantom and 6 radiotherapy patients (3 prostate, 3 brain) were split in training and test sets for evaluating the intra-patient, inter-patient and inter-anatomical region generalization performance of the trained framework. Several image similarity metrics, as well as a verification based on template matching, were used between the rendered DRRs and respective CBCT projections in the test sets, and results were compared to those of a current state-of-the-art DRR rendering method.When trained on 800 CBCT projection images from two patients and tested on a third unseen patient from either anatomical region, RealDRR outperformed the current state-of-the-art with statistical significance on all metrics (two-sample t-test, p < 0.05). Once trained, the framework is able to render 100 highly realistic DRRs in under two minutes.A novel framework for realistic and efficient DRR rendering was proposed. As the framework requires a reasonable amount of computational resources, the internal parameters can be tailored to imaging systems and protocols through on-site training on retrospective imaging data.

Citation

ID: 128171
Ref Key: dhont2020realdrrradiotherapy
Use this key to autocite in SciMatic or Thesis Manager

References

Blockchain Verification

Account:
NFT Contract Address:
0x95644003c57E6F55A65596E3D9Eac6813e3566dA
Article ID:
128171
Unique Identifier:
S0167-8140(20)30840-9
Network:
Scimatic Chain (ID: 481)
Loading...
Blockchain Readiness Checklist
Authors
Abstract
Journal Name
Year
Title
5/5
Creates 1,000,000 NFT tokens for this article
Token Features:
  • ERC-1155 Standard NFT
  • 1 Million Supply per Article
  • Transferable via MetaMask
  • Permanent Blockchain Record
Blockchain QR Code
Scan with Saymatik Web3.0 Wallet

Saymatik Web3.0 Wallet