Wearable Stretch Sensors for Human Movement Monitoring and Fall Detection in Ergonomics

Wearable Stretch Sensors for Human Movement Monitoring and Fall Detection in Ergonomics

Harish Chander;Reuben F. Burch;Purva Talegaonkar;David Saucier;Tony Luczak;John E. Ball;Alana Turner;Sachini N. K. Kodithuwakku Arachchige;Will Carroll;Brian K. Smith;Adam Knight;Raj K. Prabhu;Chander, Harish;Burch, Reuben F.;Talegaonkar, Purva;Saucier, David;Luczak, Tony;Ball, John E.;Turner, Alana;Kodithuwakku Arachchige, Sachini N. K.;Carroll, Will;Smith, Brian K.;Knight, Adam;Prabhu, Raj K.;
International journal of environmental research and public health 2020 Vol. 17 pp. 3554-
286
chander2020internationalwearable

Abstract

Wearable sensors are beneficial for continuous health monitoring, movement analysis, rehabilitation, evaluation of human performance, and for fall detection. Wearable stretch sensors are increasingly being used for human movement monitoring. Additionally, falls are one of the leading causes of both fatal and nonfatal injuries in the workplace. The use of wearable technology in the workplace could be a successful solution for human movement monitoring and fall detection, especially for high fall-risk occupations. This paper provides an in-depth review of different wearable stretch sensors and summarizes the need for wearable technology in the field of ergonomics and the current wearable devices used for fall detection. Additionally, the paper proposes the use of soft-robotic-stretch (SRS) sensors for human movement monitoring and fall detection. This paper also recapitulates the findings of a series of five published manuscripts from ongoing research that are published as Parts I to V of “Closing the Wearable Gap” journal articles that discuss the design and development of a foot and ankle wearable device using SRS sensors that can be used for fall detection. The use of SRS sensors in fall detection, its current limitations, and challenges for adoption in human factors and ergonomics are also discussed.

Citation

ID: 111553
Ref Key: chander2020internationalwearable
Use this key to autocite in SciMatic or Thesis Manager

References

Blockchain Verification

Account:
NFT Contract Address:
0x95644003c57E6F55A65596E3D9Eac6813e3566dA
Article ID:
111553
Unique Identifier:
10.3390/ijerph17103554
Network:
Scimatic Chain (ID: 481)
Loading...
Blockchain Readiness Checklist
Authors
Abstract
Journal Name
Year
Title
5/5
Creates 1,000,000 NFT tokens for this article
Token Features:
  • ERC-1155 Standard NFT
  • 1 Million Supply per Article
  • Transferable via MetaMask
  • Permanent Blockchain Record
Blockchain QR Code
Scan with Saymatik Web3.0 Wallet

Saymatik Web3.0 Wallet