Early Outcomes of Percutaneous Pulmonary Valve Implantation with Pulsta and Melody Valves: The First Report from Korea

Early Outcomes of Percutaneous Pulmonary Valve Implantation with Pulsta and Melody Valves: The First Report from Korea

Ah Young Kim;Jo Won Jung;Se Yong Jung;Jae Il Shin;Lucy Youngmin Eun;Nam Kyun Kim;Jae Young Choi;Kim, Ah Young;Jung, Jo Won;Jung, Se Yong;Shin, Jae Il;Eun, Lucy Youngmin;Kim, Nam Kyun;Choi, Jae Young;
journal of clinical medicine 2020 Vol. 9 pp. 2769-
187
kim2020journalearly

Abstract

Percutaneous pulmonary valve implantation (PPVI) is used to treat pulmonary stenosis (PS) or pulmonary regurgitation (PR). We described our experience with PPVI, specifically valve-in-valve transcatheter pulmonary valve replacement using the Melody valve and novel self-expandable systems using the Pulsta valve. We reviewed data from 42 patients undergoing PPVI. Twenty-nine patients had Melody valves in mostly bioprosthetic valves, valved conduits, and homografts in the pulmonary position. Following Melody valve implantation, the peak right ventricle-to-pulmonary artery gradient decreased from 51.3 ± 11.5 to 16.7 ± 3.3 mmHg and right ventricular systolic pressure fell from 70.0 ± 16.8 to 41.3 ± 17.8 mmHg. Thirteen patients with native right ventricular outflow tract (RVOT) lesions and homograft underwent PPVI with the new self-expandable Pulsta valve—a nitinol wire stent mounted with a trileaflet porcine pericardial valve. Following Pulsta valve implantation, cardiac magnetic resonance imaging showed a decreased PR fraction and that the right ventricular end-diastolic volume index decreased from 166.1 ± 11.9 to 123.6 ± 12.4 mL/m2. There were no mortality, severe procedural morbidity, or valve-related complications. At the mean 14.2 month (4–57 months) follow-up, no patients had more than mild PR. PPVI using Melody and Pulsta valves was first shown to provide excellent early outcomes without serious adverse event in most patients with RVOT dysfunction in Korea.

Citation

ID: 111327
Ref Key: kim2020journalearly
Use this key to autocite in SciMatic or Thesis Manager

References

Blockchain Verification

Account:
NFT Contract Address:
0x95644003c57E6F55A65596E3D9Eac6813e3566dA
Article ID:
111327
Unique Identifier:
10.3390/jcm9092769
Network:
Scimatic Chain (ID: 481)
Loading...
Blockchain Readiness Checklist
Authors
Abstract
Journal Name
Year
Title
5/5
Creates 1,000,000 NFT tokens for this article
Token Features:
  • ERC-1155 Standard NFT
  • 1 Million Supply per Article
  • Transferable via MetaMask
  • Permanent Blockchain Record
Blockchain QR Code
Scan with Saymatik Web3.0 Wallet

Saymatik Web3.0 Wallet