Rib kinematics analysis in oblique and lateral impact tests.

Rib kinematics analysis in oblique and lateral impact tests.

Jastrzębski, Dominik;Perz, Rafał;
acta of bioengineering and biomechanics 2020 Vol. 22 pp. 135-141
240
jastrzbski2020ribacta

Abstract

Understanding thorax kinematics and rib breaking mechanisms in conditions of oblique and lateral impact is crucial in safety systems development. To increase knowledge level on this subject, simulation and experimental tests are necessary. The purpose of this study was to obtain single rib kinematics in the case of oblique and lateral impact conditions using numerical simulation approach.Two impact tests using human body model of a 50th percentile man (THUMS v4.0.1 AM50) were performed in LS-Dyna R7.1.1. Impactor was a rigid cylinder with a diameter of 152 mm, and velocity equal to 6.7 m/s. Impact angle measured to sagittal plane was 30 and 90°, respectively in oblique and lateral impact case.Kinematics of ribs from 3rd to 6th were analyzed. Results shown significant similarities between oblique impact and kinematics of ribs tested in frontal impact conditions in the literature, with maximal costochondral joint displacement relatively to costovertebral joint varying from 65.4 mm (3rd rib) to 82.0 mm (5th rib). Deformation of rib in lateral impact conditions was different than during oblique impact test, with distinctive "flattening" approximately in the middle of the rib. Maximal relative displacement varies from 16.4 mm (6th rib) to 26.6 mm (5th rib) and its location depends on the analyzed rib.Oblique impact scenario may be simulated for the single rib on an experimental way using set-up of the frontal impact. Experimental simulation of the lateral impact for the single rib should not use the same set-up, as the kinematics analysis showed significant differences between simulated cases.

Access

Citation

ID: 105174
Ref Key: jastrzbski2020ribacta
Use this key to autocite in SciMatic or Thesis Manager

References

Blockchain Verification

Account:
NFT Contract Address:
0x95644003c57E6F55A65596E3D9Eac6813e3566dA
Article ID:
105174
Unique Identifier:
Network:
Scimatic Chain (ID: 481)
Loading...
Blockchain Readiness Checklist
Authors
Abstract
Journal Name
Year
Title
5/5
Creates 1,000,000 NFT tokens for this article
Token Features:
  • ERC-1155 Standard NFT
  • 1 Million Supply per Article
  • Transferable via MetaMask
  • Permanent Blockchain Record
Blockchain QR Code
Scan with Saymatik Web3.0 Wallet

Saymatik Web3.0 Wallet