Diagnostic relevance of free light chains in cerebrospinal fluid - The hyperbolic reference range for reliable data interpretation in quotient diagrams.

Diagnostic relevance of free light chains in cerebrospinal fluid - The hyperbolic reference range for reliable data interpretation in quotient diagrams.

Reiber, Hansotto;Zeman, David;Kušnierová, Pavlína;Mundwiler, Esther;Bernasconi, Luca;
clinica chimica acta; international journal of clinical chemistry 2019 Vol. 497 pp. 153-162
332
reiber2019diagnosticclinica

Abstract

Free light chains, type kappa (FLC-K), in cerebrospinal fluid (CSF) were compared to oligoclonal IgG in many studies for sensitive detection of immune reactions in brain. The missing consensus about CSF data interpretation prevents reliable conclusions. This can be overcome by a theory-based hyperbolic reference range in CSF/serum quotient diagrams.Mean Quotients for FLC-K, Q, and albumin, QAlb, of grouped, biochemically defined controls (N = 433) are fitted with the hyperbolic function Q(mean) = a/b (QAlb + b) - c by a generally applicable procedure excluding outliers.With Q(mean), the coefficient of variation CV (22.5%) and the reference range (Q(mean) ± 3 CV) we got the discrimination line Q(lim) = (3.27(QAlb + 33)-8.2) ×10 in a FLC-K Reibergram. Intrathecal FLC-K was found in 8% of another control group without OCB (N = 388) but was missed in 7% of patients with definite Multiple sclerosis (N = 95). In MS the mean intrathecal fraction was threefold larger for FLC-K (95%) compared to total IgG (36%). Similar mean quantities of intrathecal FLC-K contradict an immunological conversion between a Clinically isolated syndrome and MS.The hyperbolic reference range is superior to linear FLC-K Index (10 to 15% false negatives) and exponential curves (30% false positive interpretations for controls) in the analytical range of MS data, with excellent data fit for up to ten-fold larger QAlb values. Dynamics of the small molecule FLC-K contribute to the understanding of molecular size dependent barrier functions.

Citation

ID: 100378
Ref Key: reiber2019diagnosticclinica
Use this key to autocite in SciMatic or Thesis Manager

References

Blockchain Verification

Account:
NFT Contract Address:
0x95644003c57E6F55A65596E3D9Eac6813e3566dA
Article ID:
100378
Unique Identifier:
S0009-8981(19)31977-1
Network:
Scimatic Chain (ID: 481)
Loading...
Blockchain Readiness Checklist
Authors
Abstract
Journal Name
Year
Title
5/5
Creates 1,000,000 NFT tokens for this article
Token Features:
  • ERC-1155 Standard NFT
  • 1 Million Supply per Article
  • Transferable via MetaMask
  • Permanent Blockchain Record
Blockchain QR Code
Scan with Saymatik Web3.0 Wallet

Saymatik Web3.0 Wallet