Intraoperative optical coherence tomography measurements of aphakic eyes to predict postoperative position of 2 intraocular lens designs.

Intraoperative optical coherence tomography measurements of aphakic eyes to predict postoperative position of 2 intraocular lens designs.

Hirnschall, Nino;Farrokhi, Sanaz;Amir-Asgari, Sahand;Hienert, Julius;Findl, Oliver;
journal of cataract and refractive surgery 2018 Vol. 44 pp. 1310-1316
283
hirnschall2018intraoperativejournal

Abstract

To evaluate intraoperative anterior chamber depth (ACD) measurements of the aphakic eye to predict the postoperative ACD and compare 2 intraocular lens (IOL) designs.Hanusch Hospital, Vienna, Austria.Prospective study.In this prospective study, patients scheduled for cataract surgery received a plate-haptic IOL (Asphina, Carl Zeiss Meditec AG) or an open-loop haptic IOL (ZCB00, Johnson & Johnson). Preoperatively, optical biometry (IOLMaster 700, CZM, or Lenstar, Haag-Streit) was performed. Intraoperatively, a prototype setup was used to perform time-domain OCT scans of the anterior eye segment (Visante connected to OPMI Lumera 200, both CZM). The intraoperative ACD was measured and used to predict the postoperative IOL position. Optical biometry and subjective refraction and autorefraction (RM 8800, Topcon) were performed 2 months postoperatively.The study comprised 203 eyes of 203 patients. A partial least-square regression model for ACD generated 2 months postoperatively showed that the predictive power of the intraoperative ACD (0.48) was highest followed by the axial eye length (0.45) and then the preoperatively measured ACD (0.30). These findings were confirmed in a bootstrapping model. Regression models combining the preoperative ACD and intraoperative ACD resulted in further significant improvement.Intraoperative ACD measurements predicted the postoperative position of open-loop IOLs and plate-haptic IOLs better than preoperative ACD measurements. Combining preoperative and intraoperative ACD measurements further improved the prediction.

Citation

ID: 33766
Ref Key: hirnschall2018intraoperativejournal
Use this key to autocite in SciMatic or Thesis Manager

References

Blockchain Verification

Account:
NFT Contract Address:
0x95644003c57E6F55A65596E3D9Eac6813e3566dA
Article ID:
33766
Unique Identifier:
S0886-3350(18)30671-0
Network:
Scimatic Chain (ID: 481)
Loading...
Blockchain Readiness Checklist
Authors
Abstract
Journal Name
Year
Title
5/5
Creates 1,000,000 NFT tokens for this article
Token Features:
  • ERC-1155 Standard NFT
  • 1 Million Supply per Article
  • Transferable via MetaMask
  • Permanent Blockchain Record
Blockchain QR Code
Scan with Saymatik Web3.0 Wallet

Saymatik Web3.0 Wallet