Combination of Simple Diagnostic Tests to Detect Primary Angle Closure Disease in a Resource-constrained Region.

Combination of Simple Diagnostic Tests to Detect Primary Angle Closure Disease in a Resource-constrained Region.

Choudhari, Nikhil S;George, Ronnie;Asokan, Rashima;Khanna, Rohit;Vijaya, Lingam;Garudadri, Chandra Sekhar;
ophthalmic epidemiology 2019 pp. 1-9
234
choudhari2019combinationophthalmic

Abstract

: To report on diagnostic accuracy of van Herick (vH) technique performed by a vision technician (VT) as well as on efficacy of a combination of vH technique and central anterior chamber depth (ACD) in detection of primary angle closure disease. : Data was obtained from two cohorts; rural clinic setting (n = 111), and rural population-based research setting (n = 888). Van Herick grading was performed by a VT in first cohort and a glaucoma specialist in second cohort. A reference standard four-mirror gonioscopy was performed by a glaucoma specialist in both cohorts. We did preferential sampling. Cut-off levels for vH technique and central ACD were grade 2 and 25 percentile value, respectively. Data from one eye per participant was analyzed. : Three hundred and forty (34%) eyes were gonioscopically occludable. Area under receiver operating characteristic curve (95% confidence interval) for vH test was 0.83 (0.76, 0.9) and 0.81 (0.78, 0.84) in first and second cohorts, respectively. Simultaneous testing achieved sensitivity of 87.8% while sequential testing achieved specificity of 99.3%. Negative predictive value* of simultaneous testing was 98.3% compared to 96.6% of vH technique while positive predictive value* of sequential testing was 86% compared to 49.3% of vH technique. (*at 10% prevalence of gonioscopically occludable angle) : Diagnostic accuracy of vH grading was similar when performed by a VT and a glaucoma specialist. While test combination was effective to rule in, vH technique may suffice to rule out the disease. Implications of these findings for resource-constrained regions are discussed.

Citation

ID: 29301
Ref Key: choudhari2019combinationophthalmic
Use this key to autocite in SciMatic or Thesis Manager

References

Blockchain Verification

Account:
NFT Contract Address:
0x95644003c57E6F55A65596E3D9Eac6813e3566dA
Article ID:
29301
Unique Identifier:
10.1080/09286586.2019.1650380
Network:
Scimatic Chain (ID: 481)
Loading...
Blockchain Readiness Checklist
Authors
Abstract
Journal Name
Year
Title
5/5
Creates 1,000,000 NFT tokens for this article
Token Features:
  • ERC-1155 Standard NFT
  • 1 Million Supply per Article
  • Transferable via MetaMask
  • Permanent Blockchain Record
Blockchain QR Code
Scan with Saymatik Web3.0 Wallet

Saymatik Web3.0 Wallet