evaluation of five-year risk of lethal outcome and development of cardiovascular disorders in patients with acute myocardial infarction on basis of 0.1-hz rhythms synchronization in cardiovascular system

evaluation of five-year risk of lethal outcome and development of cardiovascular disorders in patients with acute myocardial infarction on basis of 0.1-hz rhythms synchronization in cardiovascular system

;KiselevA.R.;Gridnev V.I.;KaravaevA.S.;O.M. Posnenkova.;V.I. Ponomarenko.;M.D. Prokhorov.;B.P. Bezruchko.;V.A. Shvartz
respirology (carlton, vic) 2010 Vol. 6 pp. 328-338
205
kiseleva.r.2010saratovskijevaluation

Abstract

The research goal is to evaluate the impact of autonomic heart control indices on five-year risk of lethal outcome and development of cardiovascular disorders in patients with acute myocardial infarction (AMI) and to study the dynam¬ics of indices in short- and long-term period. 125 patients with AMI (42% female), ages 30 to 83 years, were enrolled in prospective observational study. Observation period lasted 6 years. Control checking was carried out in 1 week, 3 weeks, 6 months, 1 year and then annually. The dynamics of heart rate variability (HRV) and the synchronization of 0.1-Hz rhythms of heart and microcirculation (S) were studied during the first year. Outcomes proved to be death, MI, stroke. Development of acute heart failure Killip 2-4 and indices S < 20% during the first week of AMI (х2 = 10,5, p = 0,005 for the Cox model) played a significant role in evaluation of five-year risk of death after AMI. Sensitivity (Se) and specificity (Sp) of index S < 20% during the first week of AMI were 76% and 43% correspondingly. The Cox model showed that indices of HRV and 0.1-Hz rhythms synchronization were not of great value in evaluation of five-year risk of death after AMI. The article concludes that indices S < 20% in patients with AMI possess better prognostic value than common clinical parameters

Citation

ID: 221186
Ref Key: kiseleva.r.2010saratovskijevaluation
Use this key to autocite in SciMatic or Thesis Manager

References

Blockchain Verification

Account:
NFT Contract Address:
0x95644003c57E6F55A65596E3D9Eac6813e3566dA
Article ID:
221186
Unique Identifier:
Network:
Scimatic Chain (ID: 481)
Loading...
Blockchain Readiness Checklist
Authors
Abstract
Journal Name
Year
Title
5/5
Creates 1,000,000 NFT tokens for this article
Token Features:
  • ERC-1155 Standard NFT
  • 1 Million Supply per Article
  • Transferable via MetaMask
  • Permanent Blockchain Record
Blockchain QR Code
Scan with Saymatik Web3.0 Wallet

Saymatik Web3.0 Wallet