Monitoring breathing rate by fusing the physiological impact of respiration on video-photoplethysmogram with head movements.

Monitoring breathing rate by fusing the physiological impact of respiration on video-photoplethysmogram with head movements.

Iozzia, Luca;Lazaro, Jesus;Cerina, Luca;Silvestri, Davide;Mainardi, Luca;Laguna, Pablo;Gil, Eduardo;
physiological measurement 2019
271
iozzia2019monitoringphysiological

Abstract

The simple observation of breathing rate (BR) remains the first and often the most sensitive marker of acute respiratory dysfunction. In fact, there are evidences that drastic changes in BR are a predictive indicator of adverse events (i.e. cardiac arrest). The aim of this study is to develop a camera-based technology that may provide near-continuously estimation of BR considering the effect of respiration on videoPPG (vPPG). 
 Approach: The technology has been tested in two different experimental settings, including controlled BR and more challenging scenarios with spontaneous breathing pattern. Video data were processed offline to derive the vPPG signal. The method derives respiration from beat-to-beat PPG rate and morphology changes in amplitude and width driven by the physiological relationships between vPPG and respiration. Moreover, respiratory-induced head movements were used as additional source of information for the vPPG system. A combination of these methods has been exploited to estimate the respiratory rate every 10 second. 
 Main Results: According to the results, respiratory frequencies in the central range (0.2-0.4 Hz) may be estimated using vPPG system with low relative error, εR < 2 % and interquartile range of order IQR < 5 %. However, the vPPG system showed a drop in performance at respiratory range boundaries, around 0.1 Hz and 0.5 Hz.
 Significance: This camera-based technology can be used as ubiquitous BR monitoring system. However, vPPG-based systems should consider the effect of the BR in the estimation, mainly in applications where respiratory rate is out of the range 0.2-0.4 Hz.

Citation

ID: 34845
Ref Key: iozzia2019monitoringphysiological
Use this key to autocite in SciMatic or Thesis Manager

References

Blockchain Verification

Account:
NFT Contract Address:
0x95644003c57E6F55A65596E3D9Eac6813e3566dA
Article ID:
34845
Unique Identifier:
10.1088/1361-6579/ab4102
Network:
Scimatic Chain (ID: 481)
Loading...
Blockchain Readiness Checklist
Authors
Abstract
Journal Name
Year
Title
5/5
Creates 1,000,000 NFT tokens for this article
Token Features:
  • ERC-1155 Standard NFT
  • 1 Million Supply per Article
  • Transferable via MetaMask
  • Permanent Blockchain Record
Blockchain QR Code
Scan with Saymatik Web3.0 Wallet

Saymatik Web3.0 Wallet