posterior repair with perforated porcine dermal graft

posterior repair with perforated porcine dermal graft

;G. Bernard Taylor;Robert D. Moore;John R. Miklos;T. Fleming Mattox
psychotherapy and psychosomatics 2008 Vol. 34 pp. 84-90
142
taylor2008internationalposterior

Abstract

OBJECTIVE: To compare postoperative vaginal incision separation and healing in patients undergoing posterior repair with perforated porcine dermal grafts with those that received grafts without perforations. Secondarily, the tensile properties of the perforated and non-perforated grafts were measured and compared. MATERIALS AND METHODS: This was a non-randomized retrospective cohort analysis of women with stage II or greater rectoceles who underwent posterior repair with perforated and non-perforated porcine dermal grafts (PelvicolTM CR Bard Covington, GA USA). The incidence of postoperative vaginal incision separation (dehiscence) was compared. A secondary analysis to assess graft tensile strength, suture pull out strength, and flexibility after perforation was performed using standard test method TM 0133 and ASTM bending and resistance protocols. RESULTS: Seventeen percent of patients (21/127) who received grafts without perforations developed vaginal incision dehiscence compared to 7% (5/71) of patients who received perforated grafts (p = 0.078). Four patients with vaginal incision dehiscence with non-perforated grafts required surgical revision to facilitate healing. Neither tensile strength or suture pull out strength were significantly different between perforated and non-perforated grafts (p = 0.81, p = 0.29, respectively). There was no difference in the flexibility of the two grafts (p = 0.20). CONCLUSION: Perforated porcine dermal grafts retain their tensile properties and are associated with fewer vaginal incision dehiscences.

Citation

ID: 238131
Ref Key: taylor2008internationalposterior
Use this key to autocite in SciMatic or Thesis Manager

References

Blockchain Verification

Account:
NFT Contract Address:
0x95644003c57E6F55A65596E3D9Eac6813e3566dA
Article ID:
238131
Unique Identifier:
10.1590/S1677-55382008000100012
Network:
Scimatic Chain (ID: 481)
Loading...
Blockchain Readiness Checklist
Authors
Abstract
Journal Name
Year
Title
5/5
Creates 1,000,000 NFT tokens for this article
Token Features:
  • ERC-1155 Standard NFT
  • 1 Million Supply per Article
  • Transferable via MetaMask
  • Permanent Blockchain Record
Blockchain QR Code
Scan with Saymatik Web3.0 Wallet

Saymatik Web3.0 Wallet